Thank you for purchasing a CARRIER unit. We trust that this unit will give you complete satisfaction.
To ensure correct operation, all connections (electrical, hydraulic, etc.) must be made in accordance with best industry practice
and the regulations in force in the country of use.
Your unit must be maintained as recommended in this manual.
The unit is delivered in two separate packages.
- An air treatment module,
- An air supply / return grille,
A label on the packaging describes the unit specification. (type, model, etc.)
Each device bears a data plate. Include the reference number shown on the data plate in all correspondence.
It is the recipient's duty to inspect the contents of the packages upon receipt:
• In the event of missing items, the customer must provide the exact number of parcels delivered.
• If any damage is found on delivery, report it on the delivery receipt in the presence of the delivery driver before the delivery note is
signed.
IMPORTANT:
Claims for shortages or damage must be reported within three business days of receipt. The client must inspect
the goods in the presence of the driver. Damage / shortages must be noted at time of delivery and described in detail.
For your safety, wear protective gloves when handling.
Important:
the unit must be handled with care and stored flat. Impacts may cause damage to the frame or the body of the unit
and adversely affect its main functions and its appearance.
The unit should preferably be lifted using the brackets. It is possible to carry out the installation using a fork-lift truck, as long as care is
taken not to damage the unit.
The unit is placed inside the suspended ceiling. The unit must be fixed to the ceiling using 4 threaded rods (not supplied) on the
4 support brackets.
a - Heat exchange coil
b - Fan motor assembly
c - Electrical box
d - Main condensate drain pan
e - Auxiliary condensate drain pan
f - Condensate drain
g - Support brackets
h - Air filter
j - Air supply / return grille
k - Fresh air inlet
1. UNPACKING THE UNIT, CHECKING AND STORING
2. HANDLING
3. DESCRIPTION OF THE UNIT (Fig. 1)
3.1. Name plate (Fig. 2)
1 - Code
2 - Serial number
3 - Description of the unit
4 - Rated motor power
5 - Motor rotation speed
6 - Coil type
7 - Wiring diagram reference
8 - Motor speed wiring
9 - Maximum service pressure
10 - Electric heater specifications (if fitted).
11 - EC declaration number
The data plate contains all the information required to identify the unit and its configuration. This plate is positioned on the side
containing all the connections, above the fresh air inlet.
Before contacting us, please note the serial no. and the designation.
Summary of Contents for 42KY
Page 2: ...a j c e d b k h f g j Fig 1 3 2 1 6 10 11 8 9 5 4 Fig 2 7 ...
Page 3: ...I a b c d Fig 3 Fig 4 ...
Page 4: ...II Fig 5 c d b a 45 ...
Page 5: ...III Fig 6 a 157 131 5 67 5 60 202 18 5 40 Fig 7 Fig 8 b a Fig 9 a b ...
Page 7: ...V Fig 14 Fig 13 a Fig 16 a Fig 15 a b Fig 17 a b ...
Page 8: ...VI Fig 18 a c b d e g f ...
Page 9: ...VII Fig 21 Fig 19 b a a b Fig 20 ...
Page 19: ......
Page 38: ......
Page 39: ......