Step -1 – Getting Started

1. Connect  ductless  indoor  unit  to  touch  screen  central

controller using DLS VRF interface as instructed in the

installation manual. 

2.  Turn on the power for ductless indoor unit.

3.  Turn on the power for DLS VRF interface.

4.  Turn on the power for touch screen central controller.

5.  Select you brand based as shown below in Fig. 6 and 

press “Always” or “Just Once.”

Fig. 6 —Brand Selection

6.  Login screen will appear as shown below in Fig. 7.

•  Default login – superAdmin 
•  Default password – 66668888

7.  Press login.

Fig. 7 —Login Screen

8.  Home screen appears as shown below in Fig. 8.

Fig. 8 —Home Screen

Step – 2 – Discovering Ductless Indoor Unit

1. Press the “Install” icon on the  bottom of the screen as

shown below in Fig. 9.

Fig. 9 —Install Icon

2.  The Install screen will appear. Press “Auto Search” as 

show below in Fig. 10.

Fig. 10 —Auto Search Function

3.  The Auto search screen will appear as show below in 

Fig. 11 looking for ductless indoor units and VRF 

Summary of Contents for 40VM900010

Page 1: ...ent can be hazardous due to system pressure electrical components and equipment location Note that changes or modifications of this product are not expressly approved by the party responsible for comp...

Page 2: ...NSIONS Fig 1 Dimensional Drawing NAME OUTLINE QUANTITY FUNCTION Installation and Owners Manual 1 As reference for installation and operation Mounting Screw 3 For mounting the box 10 1 2 3 5 16 3 7 16...

Page 3: ...r in a condensing environment Do not install the device in a location where there is direct sunlight or where the temperature may become greater than 118 F 48 C or less than 4 F 20 C This product is n...

Page 4: ...controller and DLS VRF interface Fig 5 Communication Wiring CN5 CN54 CN3 CN4 CN2 ENC2 ENC1 SW7 ON 1 2 ON SW2 ON 1 2 ON CN7 CN8 RED RED BLACK BLACK Y G Y G CN1 CN6 L1 L2 To VRF controller To Touch scr...

Page 5: ...ch screen central controller and wall controller Table 6 EF and E8 Error Codes Table 7 LED 1 PORT MAX VOLTAGE V AC DC MAX CURRENT A CN54 24 1 ENC2 Set network address 0 7 ENC1 and SW7 Set IDU address...

Page 6: ...lways or Just Once Fig 6 Brand Selection 6 Login screen will appear as shown below in Fig 7 Default login superAdmin Default password 66668888 7 Press login Fig 7 Login Screen 8 Home screen appears as...

Page 7: ...he Ductless indoor unit model will always default to HWALL as shown below in Fig 14 2 To change the name of the ductless indoor unit press HWALL A pop up screen will appear with a different style of i...

Page 8: ...indoor unit address Set auxiliary heater Error codes Q What are the functions you can control through the VRF wall controller for the DLS indoor unit A The functions you can control through the VRF wa...