Use the system in the following temperature for safe and 

effective  operation.  The  Max

  operation  temperature  for 

the air conditioner (Cooling/Heating). 

If 

air conditioner is used outside the above conditions, it 

may cause the unit to function abnormally. 

 

Table 3-1 

NOTE 

 

 

Optimum  performance  will  be  achieved  within  the 

operating temperature range. 

The  following  should  be  noticed  to  ensure  economical 

operation. 

Adjust  the  air  flow  louver  properly  and  avoid  direct  air  flow  to 

room inhabitants. 

 

Adjust  the  room  temperature  properly  for  a  comfortable 

environment. Avoid excessive heating or cooling. 

 

Prevent  direct  sunlight  during  cooling  operation  by  using 

curtains or blinds. 

 

Ventilate  often.  Extended  use  requires  special  attention  to 

ventilation. 

 

Keep  doors  and  windows  closed.  If  the  doors  and  windows 

remain open, air will flow out of your room 

 a decrease 

in the cooling or heating effect. 

 

Never place objects near the air inlet or the air outlet of the unit. 

It may cause 

 effect or stop the operation. 

 

Set the timer . 

 

If you don't plan to use the unit for a long time, please take the 

batteries  from  the  remote  controller.  When  the  power  is  on, 

some energy will be consumed,even if the air conditioner isn't in 

operation. So please disconnect the power to save energy.  

Keep  the  indoor  unit  and  remote  controller  at  least  3 . 2 8 f t   ( 1 m )  

away from  televisions,  radios,  stereos,  and  other  similar  equipment.  

Fail

 to do so may cause static or distorted pictures. 

 

A dirty air filter reduce  cooling or heating efficiency, please 

clean it once 

two weeks. 

While the unit is in operation, you can adjust the air flow louver 

to  change  the  flow  direction  and  naturalize  the  room 

temperature evenly. Thus you can enjoy it more comfortably.  

Set the air flow direction.

 

Press  the  SWING  button  to  adjust  the  louver  to  the  desired 

position  and  press  this  button  again  to  maintain  the  louver  at 

this position. 

 

Adjust the air flow direction automatically.

 

Press the SWING button, the louver will swing automatically. 

While  this  function  is  set,  the  swing  fan  of 

indoor  unit  runs; 

otherwise, the swing fan doesn't run. The swing scale of every 

side is 30°. When the air conditioner isn't in operation (including 

when TIMER ON is set),  the SWING button will be invalid. 

Adjust it up and down 

      Fig 5-1 

      Fig 5-2 

Adjust it up and down 

 

Three-minute protection feature 

A  protection  feature  prevents  the  air  conditioner  from  being 

activated for approximately 3 minutes  

when it restarts immediately after operation. 

Auto-restart function  

       Power failure during operation will stop the unit completely. 

 

      When the power restores, the OPERATION indicator on the     

  

tr

a

t

s

e

r

-

o

t

u

A

????

 

e

h

t

u

o

h

ti

w

 t

i

n

u

 

e

h

r

o

F

.

g

n

i

h

s

a

lf

 

s

tr

a

t

s

 t

i

n

u

 r

o

o

d

n

  

  

  

       feature,  push the ON/OFF button on the remote controller   

      to restart the operation. For the unit with the Auto-restart  

       feature, the unit restarts automatically with all the previous  

       settings preserved by the memory function. 

Refrigerant Leakage Detection(optional):  

With this new technology, the display area 

  EC  (if 

applicable)    and  the  LED  indication  lamps  continue  flashing 

when the outdoor unit detects refrigerant leakage.  

Louver Angle Memory Function(optional):  

For some models, the machine is special designed with louver 

angle  memory  function.Power  failure  during  operation  or 

pressing the ON/OFF button on the remote controller stops 

the  unit  completely.When  the  power  restores  or 

pressing  the 

ON/OFF button on the remote controller again,the unit restarts 

automatically  with    the  previous  open  angle  of  the  horizontal 

louver by the memory function.So we strongly recommend that 

the open angle of the horizontal louver not be set too 

,in case the condensed water forms and drops from the 

horizontal louver. Press the Manual control button and the open 

angle of the horizontal louver will  

 the standard 

angle. 

imum

resulting in

a reduced heating or cooling

the 

When  the  relative  humidity  in  a  room  is  high,  it  is 

high,  it  is  normal  for  condensation  to  form  on  the  unit.

To  help  reduce  condensation,  close  the  room's  doors

and windows.

ure

s

every 

displays

by 

low

return

the 

 

Cooling operation 

Dry operation 

Heating operation 

(cooling only  type without) 

Mode

Temperature

Outdoor 
temperature 

                            (for the models with low  

                            temperature cooling system) 

temperature 

Room 

32 °F~122°F (0°C ~ 50°C) 

32 °F~122°F (0°C ~ 50°C)

5 °F~122°F (-15°C ~ 50°C)

        

5 °F~76°F (-15°C ~ 24°C ) 32 °F~86°F (0°C ~ 30°C)

 (17°C ~ 32°C)

62 °F ~ 90°F

(17°C ~ 32°C)

62 °F ~ 90°F

6.  AIR CONDITIONER OPERATIONS AND

     PERFORMANCE

7.  HINTS FOR ECONOMICAL OPERATION

8.  ADJUSTING AIR FLOW DIRECTION

19

Summary of Contents for 40MBxC Series

Page 1: ...CT INFORMATION Company Name _________________________________ Address _________________________________________ ________________________________________________ Phone Number __________________________...

Page 2: ...amage Consult a qualified installer service agency or your distributor or branch for information or assistance The qualified installer or service agency must use factory authorized kits or accessories...

Page 3: ...rill Air inlet Air inlet Air inlet Air outlet 3 9 10 11 11 12 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased dep...

Page 4: ...runs in a small room it is keep the concentration of the refrigerant if by any below the limit Otherwise oxygen in the room may be affected resulting in a serious accident The refrigerant in the air c...

Page 5: ...ure that they do not play with the appliance 2 PARTS NAMES The air conditioner consists of the indoor unit the outdoor unit the connecting pipe and the remote controller See Fig 2 Function indicators...

Page 6: ......

Page 7: ...4 REMOTE CONTROL FUNCTIONS 7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...5 USING THE REMOTE CONTROL 10...

Page 11: ...11...

Page 12: ...12...

Page 13: ...13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...tion including when TIMER ON is set the SWING button will be invalid Adjust it up and down Fig 5 1 Fig 5 2 Adjust it up and down Three minute protection feature A protection feature prevents the air c...

Page 20: ...out the grill Dismantle the air filter Clean the air filter Vacuum cleaner or pure water may be used to clean the air filter If the dust accumulation is too heavy please use a soft brush and mild dete...

Page 21: ...peration 8 2 Troubles and causes of remote controller See in Table 8 3 Symptom 1 The system does not operate Symptom 2 Change into the fan mode during cooling mode Symptom 3 White mist comes out of a...

Page 22: ...mperature sensor error F3 Outdoor EEPROM error F4 Communication malfunction between two indoor units for twins model E8 OFF F0 1 10 9 7 6 5 4 2 1 Current overload protection Indoor EEPROM error E0 OFF...

Page 23: ...letely closed Leakage of refrigerant or lack of refrigerant Table 8 2 Find reasons and solution Symptoms Causes The fan speed can not be changed Check whether the MODE indicated on the display is AUTO...

Page 24: ...11 14 40MBC 01OM...