A NOTE ABOUT SAFETY

Any time you see this symbol 

 in manuals, instructions and on

the unit, be aware of the potential for personal injury. There are
three levels of precaution:

DANGER identifies the most serious hazards which will result in
severe personal injury or death.

WARNING signifies hazards that could result in personal injury
or death.

CAUTION is used to identify unsafe practices which could result
in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in
enhanced installation, reliability, or operation.

PERSONAL INJURY, DEATH AND / OR PROPERTY
DAMAGE HAZARD

Failure to follow this warning could result in personal injury,
death or property damage.

Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock,
or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance. The
qualified installer or service agency must use
factory−authorized kits or accessories when modifying this
product.

Read and follow all instructions and warnings, including labels
shipped with or attached to unit before operating your new air
conditioner.

!

WARNING

GENERAL

The floor console fan coil unit provides quiet, maximum comfort.
In addition to cooling and/or heating, the floor console fan coil unit
matched with an outdoor condensing unit filters and dehumidifies
the air in the room to provide maximum comfort.
IMPORTANT: The floor console fan coil unit should be installed
by authorized personnel only; using approved tubing and
accessories. If technical assistance, service or repair is needed,
contact the installer. 
The floor console fan coil unit can be set up and operated from
the remote control (provided). If the remote is misplaced, the
system can be operated from the “Auto” setting on the unit.

Operating Modes:

The floor console fan coil unit has five operating modes:

S

Fan only

S

Auto

S

Heating (heat pump models only)

S

Cooling

S

Dehumidification (DRY)

Fan Only

In the FAN ONLY mode, the system filters and circulates the room
air without changing room air temperature.
Auto

In the AUTO mode, the system automatically cools or heats the
room according to the user−selected set point.
Heating

In the HEATING mode, the system heats and filters the room air.
Cooling

In the COOLING mode, the system cools, dries and filters the
room air.
Dehumidification (DRY)

In the DEHUMIDIFICATION mode, the system dries, filters and
slightly cools the room air temperature. This mode prioritizes air
dehumidification but it does not take the place of a dehumidifier.

Wireless Remote Control

The remote control transmits commands to set up and operate the
system. The control has a window display panel that displays the
current system status. The control can be secured to a surface when
used with the mounting bracket provided.

Wired Remote Control (Optional)

Summary of Contents for 40MBFQ

Page 1: ...umbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service U...

Page 2: ...eating the floor console fan coil unit matched with an outdoor condensing unit filters and dehumidifies the air in the room to provide maximum comfort IMPORTANT The floor console fan coil unit should...

Page 3: ...OFF MO DE FAN SLC SLE EP SW ING DIR ECT TUR BO CLE AN LED FOL LOW Air flow louver at air outlet Air inlet with air filter inside Installation section Wireless remote controller Display panel Drain pip...

Page 4: ...ature is O 86 F TEMP Decreases temperature in O 1 F 1 C increments Min temperature is O 62 F TIMER ON Sets timer to turn unit on TIMER OFF Sets timer to turn unit off SWING DIRECT Starts and stops lou...

Page 5: ...5 INDOOR UNIT DISPLAY PANELS A150655 Fig 3 Display Panel Fig 4 Remote Controller...

Page 6: ...lay ECO display Displays when SLEEP function is activated FOLLOW ME display Indicates that the FOLLOW ME function is on FAN SPEED display Displays selected FAN SPEED HIGH MED or LOW This display is bl...

Page 7: ...programmed after insertion of new batteries Remote Control Operation Quick Start NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the right side...

Page 8: ...erature Selecting the Fan Speed AUTO LOW MED HIGH A14362 Fig 9 Fan Speeds The fan speed can be selected by pressing FAN NOTE When the unit is on the fan runs continuously in cooling or heating When in...

Page 9: ...ioner automatically determines the appropriate blowing pattern based on the operating mode or situation Table 1 Operating Mode OPERATING MODE COOL MODE HEAT MODE Situation When the room totally cools...

Page 10: ...Use TURBO to cool or heat the room rapidly a Press TURBO An audible beep is heard if the indoor unit supports this function The fan runs on super high speed The TURBO mode terminates automatically 20...

Page 11: ...age to the coil fins Air Filters Remove and clean the air filters once a month NOTE If air filters show signs of excessive wear or are torn they must be replaced Contact your local dealer for replacem...

Page 12: ...ntrol Batteries S S S S OUTDOOR UNIT EVERY MONTH EVERY 6 MONTHS EVERY YEAR Clean Outdoor Coil from Outside Clean Outdoor Coil from Inside Blow Air Over Electric Parts Check Electric Connection Tighten...