background image

7

EQUIPMENT DAMAGE HAZARD

Failure to follow this caution may result in equipment
damage. Handle the control with care and avoid getting the
control wet.

CAUTION

!

IMPORTANT: The remote control can operate the unit from a
distance of up to 26 ft. (8 m) as long as there are no obstructions.

When the timer function is used, the remote control should be
kept in the vicinity of the fan coil (within 26 ft. / 8 m).

The remote control can perform the following basic functions:

S

Turn the system ON and OFF

S

Select operating mode

S

Adjust room air temperature set point and fan speed

S

Adjust airflow direction

Refer to the Remote Control Function section for a detailed
description of all the capabilities of the remote control.

Battery Installation

Two AAA 1.5v alkaline batteries (included) are required for
operation of the remote control.

To install or replace batteries:

1. Slide the back cover off the control to open the battery

compartment.

2. Insert batteries. Follow the polarity markings inside the

battery compartment.

3. Replace the battery compartment cover.

NOTE: 

1. When replacing batteries, do not use old batteries or a

different type battery. This may cause the remote control to
malfunction. If the remote is not going to be used for
several weeks, remove the batteries. Otherwise battery
leakage may damage the remote control.

2. The average battery life under normal use is about 6

months.

3. Replace the batteries when there is no audible beep from

the indoor unit or if the Transmission Indicator fails to light.

4. When batteries are removed, the remote control erases all 

programmed settings. The control must be reprogrammed
after insertion of new batteries.

Remote Control Operation − Quick Start

NOTE: When transmitting a command from the remote control to the
unit, be sure to point the control toward the right side of the unit. The
unit confirms receipt of a command by sounding an audible beep.

1. Turn the unit on by pushing the ON/OFF button.

2.

If there is a preference for

 

_

C rather than 

_

F (default), press

and hold the

 increase 

 and decrease 

 temperature set

point buttons together for approximately 3 seconds.

3. Select the desired mode by pushing the mode button.

AUTO

COOL

DRY

HEAT

FAN

Fig. 6 − Modes

4. Select the temperature set point by pointing the control

toward the unit and pressing the increase/decrease
temperature set point buttons until the desired temperature
appears on screen.

5. Select the desired fan speed by pressing the FAN  button.

NOTE: If the unit is operating in DRY or AUTO mode, the fan
speed will be automatically set.

6.

Set the airflow direction. When the unit is turned on, the
louvers default to the cooling or heating position. The user
can adjust the louver position of the louvers by pushing the

DIRECT 

button or have continuous louver movement by

pressing the 

SWING 

button.

Manual Operation

If the remote control is lost, damaged, or the batteries are
exhausted, the MANUAL button can be used to run the unit.

When the MANUAL  button is pressed once, the AUTO  mode
takes affect (heat or cool). When this button is pressed twice, the
system enters the TEST  mode and runs for 30 minutes in the
COOLING  mode (it runs in the AUTO  mode afterward). When
pressed three times, the system turns OFF.

Fig. 7 − Display Panel

The set conditions of manual operation are as follows:

S

Preset set point: 76

_

F (24

_

C)

S

Fan speed: AUTO 

S

Discharge air direction: Pre−set position based on operation in
“Cool”or “Heat” mode.

Summary of Contents for 40MBC-03

Page 1: ...your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFOR...

Page 2: ...o cooling and or heating the cassette fan coil unit matched with an outdoor condensing unit filters and dehumidifies the air in the room to provide maximum comfort IMPORTANT The cassette fan coil unit...

Page 3: ...Field Supplied 4 Air outlet 5 Air filter inside grille ceiling panel 6 Air inlet 7 Grille Ceiling panel Required sold separately 8 Display panel 9 Remote controller 10 Refrigerant pipe Field Supplied...

Page 4: ...O 1 F 1 C increments Min temperature is O 62 F TIMER ON Sets timer to turn unit on TIMER OFF Sets timer to turn unit off SWING DIRECT Starts and stops louver movement LED Turns indoor unit s LED disp...

Page 5: ...is warming up to prevent cold blow or when the unit goes into defrost mode OPERATION indicator This indicator flashes once per second after power is on and illuminates when the unit is in operation TI...

Page 6: ...ENT display ECO display Displays when SLEEP function is activated FOLLOW ME display Indicates that the FOLLOW ME function is on FAN SPEED display Displays selected FAN SPEED HIGH MED or LOW This displ...

Page 7: ...st be reprogrammed after insertion of new batteries Remote Control Operation Quick Start NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the ri...

Page 8: ...s can be adjusted by pressing DIRECT on the remote control The louvers can be set to remain stationary or move continuously by pressing SWING The louver position is stored in the settings however it i...

Page 9: ...he cycle cancels the operation and turn off the unit This function can be activated only on COOL or DRY mode Follow Me Mode Press FOLLOW ME to activate or deactivate this function Under this setting t...

Page 10: ...month S The air filter can prevent the dust or other particulates from entering the unit In case of blockage of the filter the working efficiency of the air conditioner may greatly diminish Therefore...

Page 11: ...nel do not use water hotter than 105_F 40 6_C and do not pour water onto the fan coil Do not use abrasive or petroleum based cleaners as they may damage the front panel CAUTION Indoor Unit Grille To c...

Page 12: ...d with dust Temperature is not set properly A window or door is open The outdoor unit is obstructed The fan speed is too low The operation mode is in Fan instead of Cool Clean the air filter Check the...