User Notice
ƹ
When operating, the entire capacity of the cooperating indoor unit should be not larger than
150% of outdoor unit. Otherwise, it will cause the shortage of cooling (heating) capacity.
ƹ
A Breaker(or fuse) need to be installed in every indoor unit, and the capacity should in according
with indoor unit’s electrical parameter; all the indoor units are required to be centralized controlled by
a total Switch, this Switch can cut off the electric power supply in case of emergency. The Breaker(or
fuse) on each indoor units have the function of short circuit prevention and abnormal overload avoiding,
it should be connected in normal situation. The total switch controlling the power supply of all the
indoor units. Before clearing and maintenance job being carried out to the indoor units, it is very
important to turn off the total power supply switch.
ƹ
In order to turn on the units successfully, the main power switch should be opened 8 hours
before the operation.
ƹ
After receiving the turn off signal, every indoor unit will continue to work for 20-70sec to make
use of the rest cool air or the rest heat air in the heat exchanger, while preparing for the next operation.
And this is normal.
ƹ
When the selected operating mode of the indoor unit are clash with the operating mode of the
outdoor unit, the malfunction light will blink after 5s on the indoor unit or remote controller showing
that the operation clash, then the indoor unit will stop. At this time, change the operation mode of the
indoor unit to the one that would not clash with the outdoor operating mode to make the operation
normal. The cooling mode is not clash with the dry mode, while the fan mode is not clash with any
mode.
ƹ
The appliance shall not be installed in the laundry.
ƹ
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should
EHFRQQHFWHGLQ¿[HGZLULQJ
ƹ
Information regarding transport/storage temperature (
-13 -131
°
F/
) is missing.
ƹ
Main switch provided by end user: main switch handle should be black or gray, it can be locked
in “OFF” position with padlock.
ƹ
The main disconnection device should be explained in user manual and the height should be
recommended at 0.6-1.7m. over current protection is required(UL 1995,CSA C22.2).
ƹ
The cooling range of the unit is the outdoor environment temp.
23-118.4 F(
-5~48°C
)
DB, the heating range of
the unit( only for the heat pump type unit) is the outdoor environment temp.
5-80.6 F(
-15~27°C
)
WB.
This product must not be disposed together with the domestic waste. This product has to be
disposed at an authorized place for recycling of electrical and electronic appliances.
°
°
-