18
Heat pump heating performance continued
See notes on pg. 20.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES
°
F
–3
7
17
27
37
47
57
EDB
CFM
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Capacity
MBtuh
Total
Power
Kw†
Total Integ*
Total Integ*
Total Integ*
Total Integ*
Total Integ*
Total Integ*
Total Integ*
38YKB024-30, 31 Outdoor Section With FB(4,5)AN(A,F)024 Indoor Section
65
650
9.57
8.81
1.68
11.7
10.7
1.73
13.7
12.5
1.77
15.8
14.0
1.82
18.1
16.5
1.87
20.6
20.6
1.93
23.3
23.3
2.02
750
9.76
8.98
1.70
11.8
10.9
1.74
13.9
12.7
1.78
16.0
14.2
1.82
18.3
16.7
1.86
20.8
20.8
1.91
23.6
23.6
1.99
850
9.94
9.14
1.72
12.0
11.0
1.77
14.1
12.8
1.80
16.2
14.4
1.83
18.5
16.8
1.86
21.0
21.0
1.91
23.9
23.9
1.98
70
650
9.32
8.57
1.73
11.5
10.6
1.79
13.6
12.4
1.85
15.7
13.9
1.90
17.9
16.3
1.95
20.4
20.4
2.02
23.1
23.1
2.11
750
9.51
8.75
1.75
11.7
10.7
1.81
13.7
12.5
1.85
15.9
14.1
1.90
18.1
16.5
1.94
20.6
20.6
2.00
23.4
23.4
2.08
850
9.68
8.91
1.78
11.8
10.9
1.83
13.9
12.7
1.87
16.0
14.2
1.90
18.3
16.7
1.94
20.8
20.8
1.99
23.6
23.6
2.06
75
650
9.04
8.31
1.79
11.3
10.4
1.86
13.4
12.2
1.92
15.5
13.8
1.98
17.8
16.2
2.04
20.2
20.2
2.12
22.9
22.9
2.21
750
9.23
8.49
1.81
11.5
10.5
1.87
13.6
12.4
1.93
15.7
14.0
1.98
18.0
16.4
2.03
20.4
20.4
2.09
23.2
23.2
2.18
850
9.41
8.66
1.84
11.6
10.7
1.89
13.8
12.5
1.94
15.9
14.1
1.98
18.2
16.5
2.03
20.6
20.6
2.08
23.4
23.4
2.16
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heaating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
FB(4,5)AN(A,F)
024
1.00
1.00
FC4BNF
024
1.00
1.00
FB4AN(A,F)
030
1.00
0.99
030
1.00
0.99
FB5AN(A,F)
030
1.00
1.02
FG3AAA
024
1.00
1.03
F(A,B)4ANF
024
1.00
1.00
CC5A/CD5AA
024
1.00
1.03
030
1.00
0.99
030
0.97
1.00
FB5BNA
030
1.00
0.99
CC5A/CD5AW
030
0.97
1.00
FK4ANF
002
0.96
0.92
CD3(A,B)A
024
1.00
1.03
FF1ANA
024
1.01
1.01
030
0.97
1.00
030
1.02
1.01
CF5AA
024
1.00
1.01
FD3ANA
024
0.99
1.02
CE3AA
024
1.00
1.01
030
1.01
1.02
030
1.00
0.99
38YKB030-30, 31 Outdoor Section With FB4AN(A,F)030 Indoor Section
65
950
14.5
13.3
2.46
17.4
16.0
2.54
20.5
18.7
2.60
23.6
21.0
2.67
27.3
24.9
2.76
31.4
31.4
2.86
36.2
36.2
3.00
1050
14.7
13.5
2.48
17.6
16.1
2.54
21.0
19.2
2.61
23.8
21.1
2.66
27.5
25.1
2.74
31.7
31.7
2.84
36.5
36.5
2.97
1150
14.8
13.6
2.50
17.7
16.3
2.56
20.8
19.0
2.61
24.0
21.3
2.66
27.7
25.2
2.73
31.9
31.9
2.82
36.8
36.8
2.95
70
950
14.2
13.1
2.56
17.2
15.8
2.64
20.3
18.5
2.72
23.4
20.8
2.79
27.1
24.6
2.88
31.1
31.1
3.00
35.8
35.8
3.14
1050
14.4
13.2
2.57
17.4
16.0
2.65
21.0
19.1
2.72
23.6
21.0
2.78
27.3
24.8
2.87
31.4
31.4
2.97
36.1
36.1
3.10
1150
14.5
13.4
2.59
17.5
16.1
2.66
20.6
18.8
2.72
23.8
21.1
2.78
27.5
25.0
2.86
31.6
31.6
2.95
36.4
36.4
3.08
75
950
13.8
12.7
2.65
17.0
15.6
2.74
20.1
18.3
2.84
23.2
20.6
2.92
26.8
24.4
3.02
30.8
30.8
3.13
35.4
35.4
3.28
1050
14.0
12.9
2.67
17.1
15.8
2.75
20.3
18.5
2.83
23.4
20.8
2.90
27.0
24.6
3.00
31.1
31.1
3.10
35.7
35.7
3.24
1150
14.2
13.1
2.69
17.3
15.9
2.77
20.4
18.6
2.84
23.6
20.9
2.90
27.2
24.8
2.99
31.3
31.3
3.08
36.0
36.0
3.21
Multipliers for Determining the Performance With Other Indoor Sections
Indoor
Section
Size
Heaating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
FB4AN(A,F)
030
1.00
1.00
FG3AAA
036
1.01
1.00
FB5AN(A,F)
030
0.99
1.03
CC5A/CD5AA
030
1.00
1.03
FB(4,5)AN(A,F)
036
1.02
1.01
036
1.01
0.98
F(A,B)4ANF
030
1.00
1.00
CC5A/CD5AW
030
1.00
1.03
036
1.02
1.01
CD5AW
036
1.01
0.98
FB5BNA
030
1.00
1.00
CD3(A,B)A
030
1.00
1.03
FK4ANF
003
1.00
0.92
036
1.01
0.98
FF1ANA
030
1.01
1.01
CF5AA
036
1.01
0.99
FC4BNF
030
1.00
1.00
CE3AA
030
1.01
1.01
033
1.01
0.97
036
1.01
0.99
036
1.02
1.01
—
—
—