SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause personal injury or property damage.
Consult a qualified installer, service agency, or your distributor or
branch for information or assistance. The qualified installer or
agency must use factory-authorized kits or accessories when
modifying this product. Refer to the individual instructions pack-
aged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves. Use
quenching cloth for brazing operations. Have fire extinguisher
available. Read these instructions thoroughly and follow all
warnings or cautions attached to the unit. Consult local building
codes and the national electric codes for special installation
requirements.

Recognize safety information. This is the safety-alert symbol

.

When you see this symbol on the unit or in instructions and
manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU-
TION. These words are used with the safety-alert symbol. DAN-
GER identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies hazards which
could result in personal injury or death. CAUTION is used to
identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.

Before installing, modifying, or servicing system, main elec-
trical disconnect switch must be in the OFF position. There
may be more than 1 disconnect switch. Lock out and tag
switch with a suitable warning label. Electrical shock can
cause personal injury or death.

INSTALLATION

Step 1—Check Equipment and Job Site

UNPACK UNIT — Move to final location. Remove carton taking
care not to damage unit.

INSPECT EQUIPMENT — File claim with shipping company
prior to installation if shipment is damaged or incomplete. Locate
unit rating plate on unit corner panel. (See Fig. 2.) It contains
information needed to properly install unit. Check rating plate to
be sure unit matches job specifications.

Step 2—Install on a Solid, Level Mounting Pad

If conditions or local codes require the unit be attached to pad, tie
down bolts should be used and fastened through knockouts
provided in unit base pan. Refer to unit mounting pattern in Fig. 2
to determine base pan size and knockout hole location.

When installing, allow sufficient space for airflow clearance,
wiring, refrigerant piping, and service. Allow 30-in. (762mm)
clearance to service end of unit and 48 in. (1219mm) above unit.
For proper airflow, a 6-in. (152mm) clearance on 1 side of unit and
12 in. (305mm) on all remaining sides must be maintained.
Maintain a distance of 24 in. (610mm) between units. Position so
water, snow, or ice from roof or eaves cannot fall directly on unit.

On rooftop applications, locate unit at least 6 in. (152mm) above
roof surface. Place unit above a load-bearing wall and isolate unit
and tubing set from structure.

Arrange supporting members to adequately support unit and
minimize transmission of vibration to building. Consult local
codes governing rooftop applications.

Step 3—Elevate Unit

Accumulation of water and ice in base pan may cause
equipment damage.

In areas where prolonged freezing temperatures are encountered,
elevate unit per local climate and code requirements to provide
clearance above estimated snowfall level and ensure adequate
drainage of unit. (See Fig. 3.)

Step 4—Replace Indoor AccuRater® Piston (if required)

Check indoor coil piston to see if it matches the required piston
shown on outdoor unit rating plate. (See Fig. 2.) If it does not

Fig. 1—Model 38YCX

A97005

IP24

Visit www.carrier.com

Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

Book 1

4

Tab

5a 5a

PC 101

Catalog No. 003-880

Printed in U.S.A.

Form 38YCX-C3SI

Pg 1

2-02

Replaces: 38YCX-C2SI

Summary of Contents for 38YCX

Page 1: ...k Equipment and Job Site UNPACK UNIT Move to final location Remove carton taking care not to damage unit INSPECT EQUIPMENT File claim with shipping company prior to installation if shipment is damaged...

Page 2: ...8 460 4 14 3 8 365 1 5 8 15 88 33 15 16 862 0 036 30 762 0 6 1 2 165 1 23 1 2 596 9 20 508 0 3 4 19 05 39 15 16 1014 4 048 30 762 0 6 1 2 165 1 23 1 2 596 9 20 508 0 7 8 22 23 33 15 16 862 0 060 30 7...

Page 3: ...e and completely sur rounds vapor tube 9 When necessary use hangar straps which are 1 in 25mm wide and conform to shape of tubing insulation See Fig 4 10 Isolate hangar straps from insulation by using...

Page 4: ...ordance with existing electrical codes Failure to follow this warning can result in an electric shock fire or death NOTE Use No 18 AWG American Wire Gage color coded insulated 35 C minimum wires If th...

Page 5: ...R G THERMOSTAT W2 L E C R G ODTS2 ODTS1 BLU VIO SYSTEMS WITH TWO OUTDOOR THERMOSTATS A97053 HEAT PUMP E L O O Y Y SYSTEMS WITHOUT OUTDOOR THERMOSTAT FB4ASX FAN COIL W2 W2 W2 C C C R R G THERMOSTAT R G...

Page 6: ...ed with a time delay relay circuit the blower runs an additional 90 sec to increase system efficiency Heating On a call for heating the thermostat makes circuits R Y and R G If phasing is correct circ...

Page 7: ...n heating mode allowing frost to accumulate on outdoor coil 4 After a few minutes in heating mode liquid line temperature should drop below closing point of defrost thermostat ap proximately 30 F NOTE...

Page 8: ...31 38ycxc3si Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations Book 1 4 Tab 5a 5a PC 101 Catalog No 003 88...

Reviews: