2-2. Operation Characteristic Curve
<Cooling> <Heating>
0
1
2
3
4
5
6
0
10 20 30 40 50 60 70 80 90 100 110 120
Compressor Speed (rps)
Cu
rren
t (
A
)
0
1
2
3
4
5
6
0
10 20 30 40 50 60 70 80 90 100 110 120
Compressor Speed (rps)
Cu
rren
t (
A
)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Outdoor : DB 35
o
C
Air Flow : High
Pip
e Length : 5m
Voltage : 230V
Conditions
Indoor : DB 20
o
C
Outdoor : DB 7
o
C/WB 6
o
C
Air Flow : High
Pip
e Length : 5m
Voltage : 230V
50
55
60
65
70
75
80
85
90
95
100
105
32
33
34
35
36
37
38
39
40
41
42
43
Cooling Capac
it
y
r
at
io (
%)
Outside Temperature (
o
C)
0
20
40
60
80
100
120
-10
-5
0
5
10
Heat
ing Capac
it
y
r
at
io (
%)
Outside Temperature ( ºC)
Conditions
Indoor : DB 27
o
C/WB 19
o
C
Indoor Air Flow : High
Pip
e Length : 5m
Voltage : 230V
Capacity ratio: 100%
2.5kW (
42NQV025M)
2.5kW (
42NQV025M-A)
Conditions
Indoor : DB 20
o
C
Indoor Air Flow : High
Pip
e Length : 5m
Voltage : 230V
42NQV025M, 42NQV025M-A
2-3. Capacity Variation Ratio According to Temperature
42NQV025M, 42NQV025M-A
<Cooling> <Heating>
FILE NO. SVM-07009
– 6 –