5. SPECIFICATION OF ELECTRICAL PARTS
5-1. Indoor Unit
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) AFS-220-20-4BR AC Motor with 150°C thermo fuse
2 Thermo. sensor (TA-sensor) ——— 10 k
Ω
at 25
°
C
3 AC-AC transformer (T01) TT-10 187 - 276V, 6VA
4 Microcomputer
5
Heat exchanger sensor
———
10 k
Ω
at 25
°
C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27 mH, 600mA
7 Diode (DB01) KBP06M 1.5A, 420V
8 Capacitor (C50) 2200
µ
F, 35 V
9 Fuse (F01) BET 3.15A, 250VAC T3.15A, 250 V
10 Regulator IC (IC08) NJM7812 12VDC, 1.5A max
11 Regulator IC (IC11) NJM7805 5VDC, 1.5A max
12 Varistor (R04) TND15G561K 560V
13 Louver motor MP24ZT DC 12V
5-2. Outdoor Unit (38NYV009E, 38NYV012E)
No.
Parts name
Model name
Rating
1 SC coil L01 GET-04051 0.6mH, 15A
(Noise filter) L03
GET-04052
2.0mH,
10A
Primary side DC280V, Secondary
2 DC-DC transformer
SWT-72
side 7.0 V x 1, 12 V x 1, 17V x 2
3 Reactor CH-51-Z-T L=19mH, 10A
4 Outside fan motor
SK
F-240-20B-
1
20W
5
G5NB-1A
Coil DC12V Contact AC250V-1.5A
6
Outside air temp.
(Inverter attached)
10
k
Ω
(
25°
C)
sensor
(T
O
sensor)
7
Heat exchanger temp.
(Inverter attached) 10k
Ω
(25
°
C)
sensor
(T
E
sensor)
9
JX0-6B
30A, 600VAC
Terminal block (6P)
10
1
1
Fuse
For protection of switching power source 3.15A, AC250V
For protection of inverter input overcurrent 25A, AC250V
1
2
Electrolytic capacitor
LLQ2G
501
KHU
BTF
500
µ
F, DC 400 V x 3 pieces
1
3
Compressor thermo.
PW-2AL
OFF: 125 ± 4°C, ON: 90 ± 5°C
Rectifier
1
4
Fan control relay
D15XB60-7001
15A, 600V
1
6
Coil-V-
4way
−
AC220-240V
ELXV350ELL222ML35S
µ
PD780024AGK
IGBT
GT15J321(Q)
15
A, 600
Compressor DA89X1C-23FZ 3-phases 4-poles 750W
1
5
8
Dischenge temp.
(Inverter attached)
62
k
Ω
(2
0
°
C)
sensor
(T
D
sensor)