background image

7

Timer Function

TIMER ON (to start the unit) and TIMER OFF (to stop the unit)

can be used separately or together.

Timer ON only

This function will allow the unit to start automatically at the set
time. The TIMER ON can be set while the unit is on or off.

UNIT ON

- Press the TIMER ON

button to initiate the auto-on time

sequence. The set time is displayed in the remote control

display. Every time the TIMER ON button is pressed, the time
will increase by 30 minutes, up to 10 h. It will increase by

60 minutes, afterwards, until the time setting reaches 24 h.

- When the TIMER ON is set, the TIMER light on unit

illuminates. The unit will continue to run at the set time.

UNIT OFF
- Set the timer described in the UNIT ON section.
- The unit will start at the set time.

Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer OFF only

This function will allow the unit to stop automatically at the set
time. The timer can be set while the unit is on or while it is off.

UNIT ON

- Press the TIMER OFF

button to initiate the auto- off time

sequence. The set time is displayed in the remote control
display. Every time the TIMER OFF button is pressed, the

time will increase by 30 minutes, up to 10 h. It will increase
by 60 minutes, afterwards, until the time settings reach 24 h.

- When the TIMER OFF is set, the timer light on the unit

illuminates and the unit turns off automatically at the set

time.

UNIT OFF
- Set the TIMER off as described in the UNIT ON section.
- The TIMER display on the unit illuminates and the unit will

remain off.

Adjust the TIMER ON settings to 0.0 to cancel this option.

Timer ON and Timer OFF

Use both functions to program the unit to turn on and shut off at

specified times.

UNIT OFF
- Set TIMER ON as previously described.
- Set TIMER OFF as previously described.
- The unit will start automatically at the set TIME ON and will

turn off at the set TIME OFF.

UNIT ON
- Set TIME OFF as previously described.
- Set TIME ON as previously described.
- The unit will turn off automatically at the set TIME OFF

and will turn on at the set TIME ON.

Sleep Mode

This mode is used to conserve energy and can be used when the
unit is in the COOL, HEAT or AUTO mode only.

Cool Mode

- Push the SLEEP button.
- After 1 hour the set point will be raised by 1.8

_

F (1

_

C).

- After another hour, the set point will be raised by another

1.8

_

F (1

_

C) and the fan will run in low speed.

- The unit will shut off 5 hours after setting the SLEEP mode.
- The SLEEP mode will be cancelled if either the “Mode”,

“TEMP”, “Fan”, “Timer”, or “On/Off” buttons on the

remote control is pressed.

Heat Mode

- Same as cooling mode but set points will be lowered by

1.8

_

F (1

_

C).

Turbo Mode

Use the TURBO mode to cool or heat the room rapidly.

- Press the TURBO button. An audible “beep” will be heard

if the indoor unit supports this function.

- The fan will run on super high speed.
- The TURBO mode terminates automatically after 20 minutes

from pushing the Turbo mode button. It can be terminated
immediately by pushing the Turbo mode again. When the

Turbo mode is terminated, the unit will go back to the
original setting.

Resetting the Remote Control

If the batteries in the remote control are removed, the current settings
will be cancelled and the control will return to the initial settings and

will be in standby mode. Push the ON/OFF button to activate it.

Time Delay

If the On/Off button is pressed too soon after a stop, the
compressor will not start for 3 to 4 minutes due to the inherent

protection against frequent compressor cycling. The unit will only

emit an audible beep when the signals are received correctly.

Heating Features

If the unit is in the heating mode, there will be a delay when the
fan starts. The fan will start only after the coil is warmed up to

prevent cold blow.

Auto Defrost Operation

In heating mode, if the outdoor coil is frosted, the indoor fan and

outdoor fan will turn off while system removes the frost on the
outdoor coil.
The system will automatically revert to normal operation when

frost is removed from the outdoor unit.

Auto Start

If the power fails while the unit is operating, the unit stores the
operating condition, and it will start operation automatically under

those conditions when the power is restored.

Self Clean Mode

Press the “Self Clean” button to activate or deactivate the

self- cleaning function. Under this function, the air conditioner will
automatically clean and dry the evaporator..

Follow Me Mode

Press the “Follow Me” button to activate or deactivate this

function. Under this setting, the temperature displayed in the

remote control is the actual temperature at its location. The remote
control will send this signal to the air conditioner every 3 minutes.

This function is not available for DRY and FAN modes.

LED / F.P. Mode

Press the LED button to turn the display light on and off. Press the
“F.P.” button for approximately 2 seconds to activate or deactivate the

freeze protection mode. The indoor unit will display “FP”.
This function is only available in the heating mode for heat pumps.
Under this function, the unit will operate at high fan speed and the

coil temperature will be automatically set to 46

_

F (8

_

C).

This mode can also be deactivated by pressing the “On/Off”,
“Sleep”, “Mode”, “Fan”, or either “TEMP” buttons.

Summary of Contents for 38MAQ Series

Page 1: ...ipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model...

Page 2: ...addition to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall...

Page 3: ...HE AT FA N HIG H ME D LO W F P 2 1 3 4 5 6 7 8 9 10 12 11 1 Front panel 2 Air Inlet 3 Display 4 Air Filter 5 Horizontal airflow grille 6 Vertical air flow louver 7 Interconnecting tubing 8 Control and...

Page 4: ...Displays the temperature setting 62 F 86 F When you set the operating mode to FAN no temperature setting is displayed And O O ifin the TIMER mode shows the ON and OFF settings of the TIMER Displayed b...

Page 5: ...ion Indicator fails to light 5 When batteries are removed the remote control erases all programmed settings The control must be reprogrammed after insertion of new batteries Remote Control Operation Q...

Page 6: ...peed AUTO LOW MED HIGH A14362 The fan speed can be selected by pressing the FAN button NOTE When the unit is on the fan will run continuously in cooling or heating When in heating there might be situa...

Page 7: ...s on the remote control is pressed Heat Mode Same as cooling mode but set points will be lowered by 1 8_F 1_C Turbo Mode Use the TURBO mode to cool or heat the room rapidly Press the TURBO button An a...

Page 8: ...follow this caution may result in equipment damage When cleaning the front panel do not use water hotter than 105_F 40 6_C and do not pour water onto the fan coil Do not use abrasive or petroleum bas...

Page 9: ...ce representative Call your service representative Cooling is Not Working Properly The filter is blocked with dust Temperature is not set properly A window or door is open The outdoor unit is obstruct...

Page 10: ...7310 W Morris St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM 38 40MA 02 Replaces 38 4...

Reviews: