22
Zone B: Elevate or keep or descend the frequency of compressor.
Zone H: Compressor stops after running as the minimum frequency for 60 minutes or
ΔT is less than -2
℃
.
8.5.2 Indoor heat exchanger anti-freezing function.
If T2 is lower than 0
℃
, the compressor stops and resumes when T2>5
℃
.
8.5.3 Outdoor unit current control in cooling mode(refer to the parameter table)
8.5.4 Rating capacity test function
1) Set the indoor unit with remote controller as: high fan, 17
℃
in cooling mode, then press
“TURBO” button on controller
6 times or more within 10 seconds(make sure indoor unit receives these signals), the machine will turn into rating capacity
test mode, the buzzer will make a
“di” sound for 2 seconds continuously. Also, indoor fan will change to rating speed, the
frequency of compressor will be fixed as rating value. Any condition of above is not satisfied, the machine can not be
turned into rating capacity test mode.
2) The machine will quit from the rating capacity test mode if running for 5 hours or changing fan speed or
setting temperature.
8.5.5 Turbo function(press the
“TURBO” button on remote controller)
Elevate current frequency to a higher grade. Indoor fan turns to turbo speed.
After running for 30 minutes the machine will turn back to previous setting mode.
8.5.6 Indoor fan operation rule.
In cooling mode, indoor fan runs all the time and the speed can be selected as high, medium, low and auto.
Auto fan in cooling mode acts as follow:
8.5.7 Condenser high temperature protection function(in cooling and drying mode)
If T
3>
60
℃
for 5 seconds, compressor will stop immediately, and the machine will not resume until T
3<
52
℃
.
8.6 Drying mode
8.6.1 Indoor fan speed is fixed at breeze grade and can
’t be changed. The horizontal angle is the same as in cooling
mode.
8.6.2 Room overlow temperature protection
I3COOL
I2COOL
I1COOL
comp. pause
freq. descends if curr. rises;
freq. remains if curr. descends
running normally
o
u
td
o
o
r u
n
it
c
u
rre
n
t
Δ
T=
(o
o
m
te
m
p
)
–
(s
e
tt
in
g
T
e
m
p
)
medium
4.0
3.0
1.5
1.0
℃
high
low