background image

Summary of Contents for 38GXM series

Page 1: ...ng the installation 38GXM 40GXM TABLE OF CONTENTS PAGE PARTS LIST 2 SAFETY CONSIDERATIONS 3 SYSTEM REQUIREMENTS 3 DIMENSIONS 4 CLEARANCES 5 INSTALLATION GUIDE 6 INDOOR UNIT INSTALLATION 6 OUTDOOR UNIT...

Page 2: ...Mounting Screws Remote Control Remote Control Holder Conversion Joint A09653 A09655a _rontPane _ _irin L I Lou_ver__ IN Display Closeul6 Remote control Remote control holder Drain Hose Air intake Air...

Page 3: ...ength is buried refrigerant may nfigrate to the cooler buried section during extended periods of system shutdown This causes refrigerant slugging and could possibly damage the compressor at start up G...

Page 4: ...70 9 8 249 7 84 199 18 7 8 5 12k 32 7 831 11 2 284 8 9 226 24 2 11 18k 40 2 1021 12 2 310 9 0 229 28 6 13 DIMENSIONS OUTDOOR uu HH HHN _u W A08290 W D H Net Operating Weight Unit Size In mm In mm In m...

Page 5: ...R CEILING J 6 0 15m _mi n 6 i 8m FLOOR Fig 2 Indoor unit clearance A07891 CLEARANCES OUTDOOR IA Air inlet __L c Air outle A07894 UNIT 12kin mm A 20 508 B 20 508 C 24 610 D 12 305 E 24 610 Fig 3 Outdoo...

Page 6: ...e mounting plate to the wall cp Fig 4 9k Mounting Plate Spacing cp 95 A085862 21 93 557 5 Note Units in mm Fig 5 12k Mounting Plate Spacing A08291 Fig 6 18k Mounting Plate Spacing A09655 FOR EACH FAN...

Page 7: ...cation does not require them at the current time The system can be expanded at any time 3 Conversion joints are supplied with the outdoor unit They are required for certain fan coil combinations Refer...

Page 8: ...it interconnecting wiring into back side of indoor unit Hang indoor unit on upper hooks of wall mounting plate as shown in Fig 12 A08283 Fig 12 Hanging Indoor Unit 5 Open front cover of indoor unit an...

Page 9: ...e _ _ _ __ _7 High side valve Charge hose _ _ Charge hose i__ l _ _Vacuumpump Y Low side valve Fig 15 Manifold A07361 Deep Vacuum Method The deep vacuum method requires a vacuum pump capable of pullin...

Page 10: ...through which the cables and tubing pass INDOOR UNIT 1 Do all Remote Control buttons flmction properly 2 Do the display panel lights work properly 3 Does the air deflection louver function properly 4...

Page 11: ...mistor 2 Unit A Leaving Indoor Coil Temperature Thermistor 3 Unit A Entering Indoor Coil Temperature Thermistor 4 Unit A Indoor Air Temperature Thermistor 5 Unit A Heating Cooling Mode Conflict with U...

Page 12: ...ssor Ramping Down Due to Unit C 7 High ID Coil Temperature Compressor Ramping Down Due to Unit D 8 High ID Coil Temperature Defrost Mode 9 Max Comp Speed Reached Due to High 1 Leaving OD Coil Air Temp...

Page 13: ...Units 6 Unit C Indoor Coil Freeze Protection 7 Unit C Indoor Coil High Temperature 8 Protection Communication Error With Unit D 1 Unit D Mid Indoor Coil Temperature 2 Thermistor Unit D Leaving Indoor...

Page 14: ...ris St Indianapolis IN 46231 Printed in U S A Edition Date 03 11 Manufacturer reserves the right to change at any time specification8 and design8 without notice and without obligations 14 Catalog No 3...