O

Warmer & Cooler Commands in Auto Changeover

If the thermostat is configured to Auto 
Heat/Cool changeover:

WARMER button press while in Auto or Off 
mode:

When the thermostat receives a warmer command 
(button press) through the remote control, and the 
heater is not running, the set points will be raised  
to start the heater operation.  If the heater is 
running upon a Warmer button press, the set points 
will be raised 2 degrees.
The remote control receiver will allow up to 3 
successive Warmer button presses.  After the 3rd 
successive Warmer button press, the IR receiver 
will not accept an additional Warmer button press 
for 1 minute.  

When the thermostat receives a Warmer command 
(button press) and the air conditioner is running, the 
set points will be raised so that the Cool set point is 
the same as the present room temperature which 
will then turn off the air conditioner.   The thermostat 
will not accept another Warmer button press for 10 
seconds.

Summary of Contents for 33CSIRRCVR-01

Page 1: ...R S MANUAL Thermostat Remote Control Receiver Thermostat Remote Control Receiver Allows remote control operation of basic thermostat functions Unique Warmer Cooler commands Compatible with thermostat...

Page 2: ...e control to the receiver is uni directional without feedback to the user It is because of this uni directional control we have created a unique control algorithm for this remote system The Warmer and...

Page 3: ...as off prior to a Warmer or Cooler button press the system will turn on in the last mode Auto or Manual changeover of operation prior to pressing Off Press the Fan On button for continuous fan operati...

Page 4: ...This occurs even if the thermostat was Off When the thermostat receives a Warmer command and the heater is running the set point will be raised 2 degrees above the present set point WARMER button pres...

Page 5: ...hermostat was Off When the thermostat receives a Cooler command and the air conditioning is running the set point will be lowered 2 degrees below the present set point Cooler button press while in Hea...

Page 6: ...button press the set points will be raised 2 degrees The remote control receiver will allow up to 3 successive Warmer button presses After the 3rd successive Warmer button press the IR receiver will...

Page 7: ...et points will be lowered 2 degrees The remote control receiver will allow up to 3 successive Cooler button presses After the 3rd successive Cooler button press the IR receiver will not accept an addi...

Page 8: ...at mode The following will occur if the Warmer button is pressed while the thermostat is off The thermostat changes from Off to Heat The set point is raised to start heater operation Example 3 The the...

Page 9: ...to the thermostat insert the IR receiver plug into the accessory Jack of the thermostat The receiver will lock into the ventilation slots of the thermostat To remove the IR receiver from the thermosta...

Page 10: ...Remote Control Battery Replacement Page 10 Replace battery with CR 2025 or equivalent Battery Door Front View Rear View...

Page 11: ...OEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS ALL REPLACEMENT PARTS WHETHER NEW OR REMANUFACTURED ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TI...