Carrier 33CSCPACHP-01 Owner'S Manual Download Page 4

4

Turning Heating and Cooling System Off  —

To use the thermostat to turn the heating and cooling system

off, perform the following procedure:

1. Open the thermostat front panel door.
2. Press the 

mode

 button until the display shows "off" in the

upper left corner.

3. Close the thermostat door.

Advanced Programming  — 

The user can customize

two different features on the thermostat, the Fahrenheit or Cel-

sius display and the backlighting of the thermostat. 
FAHRENHEIT OR CELSIUS DISPLAY  — The thermostat

is preset to display the temperature in degrees Fahrenheit. The

user can change the display to Celsius if desired. To change the

display, perform the following procedure:

1. Open the thermostat front panel door.
2. Press and hold the 

OCC

 and 

LIMIT

 buttons simultane-

ously for three seconds. The screen will display flashing

"U2" and the F or C setting.

3. Press the 

mode

 button to change the flashing “U2” to the

F or C setting.

4. Press the 

up 

or

 down

 button to select either F or

 

C.

5. Press the

 fan

 or

 done

 button.

6. Close the thermostat door.

BACKLIGHTING  — The thermostat can be set to have the

backlighting either Off or On. To change the backlighting se-

lection, perform the following:

1. Open the thermostat front panel door.
2. Press and hold the 

OCC 

and 

LIMIT

 buttons simultane-

ously for three seconds. The screen will display a flashing

"U2", press the up button to display the flashing "U3" and

the On or Off backlight setting. 

3. Press the 

mode

 button to change the flashing “U3” to the

On (or Off).

4. Press the 

up 

or

 down

 button to select On or Off.

5. If Off is selected, the thermostat backlight will normally

be off. It will turn on with any button press and stay on for

10 seconds between button presses. After 10 seconds of

no button presses, the backlight turns off until another

button press occurs. 

6. If On is selected, the thermostat backlight will normally

be on and dim in appearance. The backlight brightness

becomes brighter with any button press and remains

bright for 10 seconds. After 10 seconds of no button

presses, the backlight returns to a dimmer level until an-

other button press occurs. 

7. To exit the user configuration screen, press the 

fan

 or the

done

 button.

8. Close the thermostat door.

Using the Fan — 

The thermostat is factory configured so

that the fan runs continuously (Fan On mode) during the occu-

pied or limit period. If the installer has configured the thermo-

stat to allow operation in the Fan Auto mode, the fan will run

only when heating or cooling is required. To change the fan set-

ting:

1. Open the thermostat front panel door.
2. Press the

 fan

 button on the left side. The fan on or fan

auto will appear in the lower left corner of the display.

3. Press the 

fan

 button again to change setting.

4. Close thermostat door.

Auto Changeover  — 

The thermostat displays one of

five modes: heat, cool, Em heat, heat cool (auto mode) and off.

When the mode selection is in auto mode, the system is al-

lowed to switch from heating to cooling or from cooling to

heating to maintain the temperature set points.

Unlocking the Keypad — 

The thermostat is locked

when the padlock symbol is shown on the thermostat display.

A locked thermostat will inhibit a user from making adjust-

ments. 

The method by which the thermostat is unlocked is config-

ured by the installer. Three unlocking options are available:

1. The user must simultaneously depress the 

up 

and

 down

buttons for 5 seconds.

2. If a set of dashes are displayed, then a four-digit pass code

must be entered by the user.

3. The user must simultaneously depress the 

up 

and

 down

buttons for 5 seconds, and then enter a four-digit pass

code.

Auxiliary Heat  — 

This option is available for all of the

equipment types except cool only.  When the auxiliary heat is

active "aux heat" will be displayed and the supplemental heat is

used to meet the demand in the space.  The heater will turn on

automatically.

Using Emergency Heat — 

Emergency heat is used

when the heat system cannot keep up with demand. If the heat

pump compressor that works with auxiliary heat fails, or if the

heat pump is not working at all, the emergency heat can be

used. To set the thermostat to use emergency heat, perform the

following procedure:

1. Open the thermostat front panel door.
2. Press the 

mode

 button until the display shows Em Heat

in the upper left corner of the display.

3. Close the thermostat door.

Smart Recovery  — 

The Smart Recovery feature transi-

tions the space from one temperature period (P1 - P4) to the

next so that the space temperature matches the temperature set

point at the start of each time period. This means, for example,

that if the occupied period temperature setting is lower than the

period that precedes it, then the thermostat will start cooling

down the space before the beginning of the scheduled period.

The thermostat does this at an energy efficient rate. This not

only helps make the space as comfortable as possible, it also

makes thermostat usage more effective.

Power Outage  — 

If the building loses electricity, the

thermostat will not need to be reprogrammed. The settings are

retained in memory.

cool

hold

fan

auto

OCC

LIMIT

UNOCC

push and hold to set

set

schedule

days

period start time

set

clock

d/h/m

mode

fan

done

hold

run

Fig. 4 — Holding Temperature Set Points

a33-9219

Summary of Contents for 33CSCPACHP-01

Page 1: ...w ing buttons are located on the thermostat display See Fig 1 for button locations FAN 1 Selects whether the fan operates continu ously on or only when needed for heating or cooling auto HOLD RUN 2 Holds the currently selected temper ature or runs the scheduled program MODE 3 Selects whether thermostat is set for heat ing cooling emergency heat auto heat and cool as needed or off UP 4 Increases th...

Page 2: ...s required only the heating set point should be shown in the display To change which modes are dis played continue to press the mode button until the de sired modes of operation are displayed 7 Press the hold run button to save these settings Using OCC UNOCC and LIMIT Buttons When the user presses the OCC UNOCC or LIMIT button the preset temperature settings will be viewed and a triangle icon will...

Page 3: ...red temporary changes that require user confirma tion by either closing the door or pressing the done button which would confirm any changes made up to that point If dashes appear in the display this is an indication that the start time in the period displayed is not the same start time in all periods Press the start time and update the time for the HVAC equipment to start Temporary Hold Override ...

Page 4: ...pen the thermostat front panel door 2 Press the fan button on the left side The fan on or fan auto will appear in the lower left corner of the display 3 Press the fan button again to change setting 4 Close thermostat door Auto Changeover The thermostat displays one of five modes heat cool Em heat heat cool auto mode and off When the mode selection is in auto mode the system is al lowed to switch f...

Page 5: ...at uses electricity the batteries if installed take over if the electricity goes out When powered by batteries the thermostat s two AA batter ies should last about one year When the batteries have lost about one third of their power a battery icon shows up on the display in the upper right corner with two black bars If two thirds of battery power is lost the battery icon will display one black bar...

Page 6: ......

Page 7: ......

Page 8: ...ht to discontinue or change at any time specifications or designs without notice and without incurring obligations Catalog No 04 53330022 01 Printed in U S A Form 33CS 22SO Pg 8 8 11 Replaces New Copyright 2011 Carrier Corporation ...

Reviews: