Carrier 338106-754-CBP Installation Instructions Manual Download Page 5

5

S

Low temperature rise: Set unit for correct temperature rise range
as shown on unit rating plate.

S

Contaminated combustion air: Remove contaminates or provide
ample fresh air for combustion.

S

Excessive amounts of outside ventilation air: Return air
temperature cannot be below 60 degrees F for extended periods
of time.

S

Incorrect venting or termination: Recirculation of products of
combustion into the combustion air pipe can damage the
furnace. Verify proper venting and vent termination per

installation instructions. For additional information, and a
complete sequence of furnace operation, refer to furnace
Installation, Start--Up and Operating Instructions.

16. After System Check--out is complete, set thermostat below

room temperature.

17. Verify that burner shuts down and blower completes selec-

ted off delay time.

18. Verify furnace operates properly and set thermostat to de-

sired room temperature.

19. Re--install outer doors.

Figure 4

Blower Assembly

338106

Summary of Contents for 338106-754-CBP

Page 1: ...asses and work gloves Have a fire extinguisher available WARNING FIRE EXPLOSION ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death and or property damage The ability to properly perform maintenance on this equipment requires certain knowledge mechanical skills tools and equipment If you do not possess these do not attempt to perform any maintenance on this...

Page 2: ... combustion air pipe supports and move the pipes out of the way Secure the pipes if necessary Otherwise it will be necessary to cut the pipes at a point external to the furnace casing 5 After disconnecting or cutting the vent and combustion air pipes loosen both clamps at the vent and combustion air pipe grommets attached to the blower shelf of the furnace See Figure 1 and Figure 3 NOTE If the gro...

Page 3: ...ower housing and set the bracket aside 6 Remove the screws that secure the blower cut off to the blower housing 7 Remove the blower cut off and set aside 8 Loosen the blower wheel set screw until wheel spins freely on motor shaft 9 Remove the bolts that attach the blower motor mounting arms to the blower housing 10 Remove the blower motor 11 Remove the blower wheel from the housing 12 Remove the m...

Page 4: ... or property damage Never purge a gas line into a combustion chamber Never test for gas leaks with an open flame Use a commercially available soap solution made specifically for the detection of leaks to check all connections A fire or explosion may result causing property damage personal injury or loss of life WARNING RISQUE D EXPLOSION ET D INCENDIE Le non respect des avertissements de sécurité ...

Page 5: ...cts of combustion into the combustion air pipe can damage the furnace Verify proper venting and vent termination per installation instructions For additional information and a complete sequence of furnace operation refer to furnace Installation Start Up and Operating Instructions 16 After System Check out is complete set thermostat below room temperature 17 Verify that burner shuts down and blower...

Page 6: ...is St S Indianapolis IN 46231 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No IIK 338106 02 Printed in U S A Edition date 09 11 Replaces IIK 338106 01 338106 ...

Reviews: