25HCB5

Comfort

t

15 Series Heat Pump

with Puron

r

Refrigerant

1---1/2 To 5 Nominal Tons (Sizes 18 To 60)

Product Data

the environmentally sound refrigerant

Carrier’s heat pumps with Puron

r

refrigerant provide a collection

of features unmatched by any other family of equipment. The

25HCB5 has been designed utilizing Carrier’s Puron refrigerant.

The environmentally sound refrigerant allows consumers to make
a responsible decision in the protection of the earth’s ozone layer.
As an Energy Star

r

Partner, Carrier Corporation has determined

that this product meets the Energy Star

r

guidelines for energy

efficiency. Refer to the combination ratings in the Product Data

for system combinations that meet Energy Star

r

guidelines.

NOTE

:

Ratings contained in this document are subject to

change at any time. Always refer to the AHRI directory
(www.ahridirectory.org) for the most up--to--date ratings
information.

INDUSTRY LEADING

FEATURES / BENEFITS

Efficiency

S

15 SEER/ 11.2 -- 13.0 EER/ 7.7 -- 8.8 HSPF (Nominal)

S

Microtube Technology

t

refrigeration system

S

Indoor air quality accessories available

Sound

S

Sound level as low as 70 dBA

Comfort

S

System supports Thermidistat

t

or standard thermostat

controls

Reliability

S

Puron

r

refrigerant -- environmentally sound, won’t

deplete the ozone layer and low lifetime service cost.

S

Front--seating service valves

S

Scroll compressor

S

Internal pressure relief valve

S

Internal thermal overload

S

High pressure switch

S

Loss of charge switch

S

Filter drier

S

Balanced refrigeration system for maximum reliability

Durability

WeatherArmor

t

protection package:

S

Solid, durable sheet metal construction

S

Steel louver coil guard

S

Baked--on, complete coverage, powder paint

Applications

S

Long--line -- up to 250 feet (76.20 m) total equivalent length,
up to 200 feet (60.96 m) condenser above evaporator, or up to
80 ft. (24.38 m) evaporator above condenser (See Longline
Guide for more information.)

S

Low ambient (down to --20

_

F/--28.9

_

C) with accessory kit

Summary of Contents for 25HCB5

Page 1: ...ratings information INDUSTRY LEADING FEATURES BENEFITS Efficiency S 15 SEER 11 2 13 0 EER 7 7 8 8 HSPF Nominal S Microtube Technologyt refrigeration system S Indoor air quality accessories available S...

Page 2: ...are critical to achieve rated capacity and efficiency Installation of this product should follow all manufacturing refrigerant charging and air flow instructions Failure to confirm proper charge and...

Page 3: ...le total equivalent length is up to 250 ft 76 2 m The maximum vertical separation is 200 ft 60 96 m when outdoor unit is above indoor unit and up to 80 ft 24 38 m when the outdoor unit is below the in...

Page 4: ...udes Outdoor Air Temperature Sensor TSTATCCPHH01 B HybridHeatt Dual Fuel Thermostat Auto Changeover 7 Day Programmable F C Includes Outdoor Sensor TSTATXXSEN01 B TSTATCCPHP01 B Thermostat Auto Changeo...

Page 5: ...cycles Improves compressor lubrication on restart and minimizes the chance of liquid slugging Usage Guideline Required in low ambient cooling applications Required in long line applications Suggested...

Page 6: ...o allow for drainage from unit base Usage Guideline Suggested in the following applications Heat pump installations in heavy snowfall areas Heat pump installations in snow drift locations Heat pump in...

Page 7: ...le tables of the NEC ANSI NFPA 70 Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2 Time Delay fuse FLA Full Load Amps LRA Locked Rotor...

Page 8: ...8 DIMENSIONS ENGLISH 25HCB5...

Page 9: ...9 DIMENSIONS SI 25HCB5...

Page 10: ...0 FX4CN B F 060 25HCB548A30 FX4CN B F 060 25HCB542A30 FX4CN B F 048 25HCB536A30 FX4CN B F 042 25HCB530A30 FX4CN B F 036 25HCB524A30 FX4CNF030 25HCB518A30 FX4CNF018 BASED ON INDOOR ENT AIR AT 70 F 21 C...

Page 11: ...ious examples Wall Wall Wall Wall 24 Service 6 152 4 mm 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 Service 24 609 6 24 609 6 24 609 6 12 304 8 12 304 8 12 304 8 12 304 8 6 152 4 Note...

Page 12: ...68 8 2 10200 2 38 3106263 25HCB518A30 CSPH 2412A 58MEB060 12 17500 12 0 15 00 17400 3 56 7 8 10100 2 32 3032212 25HCB518A30 CSPH 2412A 58MV B C 040 14 17400 11 7 14 75 17400 3 5 7 7 10100 2 30 303221...

Page 13: ...00 2 62 3032246 25HCB524A30 CNPV 3014A TDR 23400 11 2 13 50 24000 3 6 8 4 15300 2 52 3032250 25HCB524A30 CNPV 3017A 58CV A X 090 16 23400 12 8 15 50 23600 3 72 8 5 14400 2 64 3106273 25HCB524A30 CNPV...

Page 14: ...3 0 15 50 29000 3 62 8 3 17200 2 50 3032355 25HCB530A30 CNPH 3017A 58CV A X 110 20 28800 13 0 15 50 29000 3 62 8 3 17200 2 50 3032356 25HCB530A30 CNPH 3017A 58CV A X 135 22 28800 13 0 15 50 29000 3 64...

Page 15: ...25HCB530A30 CSPH 3612A 58CV A X 070 12 29200 13 0 15 50 29400 3 72 8 4 17400 2 54 3032391 25HCB530A30 CSPH 3612A 58CV A X 090 16 29400 13 0 16 00 29200 3 74 8 4 17300 2 56 3032392 25HCB530A30 CSPH 36...

Page 16: ...20 34000 12 5 15 00 35000 3 54 8 2 20800 2 50 3032432 25HCB536A30 CNPH 3617A 58PH 045 08 34000 11 5 14 00 35600 3 5 8 0 21400 2 46 3032433 25HCB536A30 CNPH 3617A 58PH 070 16 34000 12 0 14 50 35400 3...

Page 17: ...12A 58PH 110 20 35400 13 0 15 50 35600 3 82 8 6 21200 2 64 3032506 25HCB536A30 CSPH 3612A TDR 35200 12 0 14 00 36000 3 7 8 2 22200 2 52 3032525 25HCB536A30 CSPH 4212A 58CV A X 070 12 35000 12 5 15 00...

Page 18: ...0 3 58 8 3 25800 2 58 3106382 25HCB542A30 CNPH 4221A 58MEB080 16 41500 12 0 14 50 41500 3 54 8 2 25600 2 56 3106383 25HCB542A30 CNPH 4221A 58MEB100 20 41500 12 0 14 50 41500 3 58 8 3 25600 2 58 310638...

Page 19: ...2000 3 68 8 5 25800 2 62 3106395 25HCB542A30 CSPH 4212A 58MEB100 20 42000 12 5 15 00 42000 3 72 8 6 25800 2 64 3106396 25HCB542A30 CSPH 4212A 58MEB120 20 42000 12 5 15 50 42000 3 76 8 6 25800 2 66 303...

Page 20: ...2 28600 2 54 3106415 25HCB548A30 CNPH 4821A 58MEB120 20 46500 12 0 14 50 45000 3 62 8 2 28600 2 54 3032699 25HCB548A30 CNPH 4821A 58MV B C 080 20 46000 12 0 14 00 45000 3 5 8 0 28800 2 48 3032700 25H...

Page 21: ...CAP 6021A TDR 56500 11 2 13 50 57500 3 64 8 3 35800 2 56 3032764 25HCB560A30 CAP 6024A 58CV A X 135 22 56500 11 5 14 00 57000 3 66 8 3 35400 2 60 3032765 25HCB560A30 CAP 6024A 58CV A X 155 22 57000 1...

Page 22: ...19 4 19 78 14 64 1 14 18 74 14 22 1 30 17 67 13 79 1 49 16 65 13 38 1 70 15 78 13 03 1 90 15 10 12 76 2 05 63 17 2 18 30 14 08 1 15 17 31 13 64 1 32 16 31 13 21 1 51 15 34 12 79 1 72 14 53 12 44 1 91...

Page 23: ...0 97 58CV A X 070 12 CAP 3014A 0 98 0 98 58CV A X 070 12 CNPH 2417A 0 97 1 01 58CV A X 070 12 CNPH 3017A 0 98 0 98 58CV A X 070 12 CNPV 2414A 0 97 1 01 58CV A X 070 12 CNPV 3014A 0 98 0 98 58CV A X 0...

Page 24: ...20 20 CSPH 3012A 0 99 0 99 58MV B C 120 20 CAP 2414A 0 98 1 02 58PH 045 08 CAP 3014A 0 99 0 99 58PH 045 08 CNPH 2417A 0 97 1 02 58PH 045 08 CNPH 3017A 1 00 1 00 58PH 045 08 CNPV 2414A 0 97 1 02 58PH 0...

Page 25: ...17A 0 99 1 07 CNPV 3617A 0 99 1 07 CNPV 3621A 0 99 1 07 CSPH 3012A 0 99 1 08 CSPH 3612A 1 01 1 08 CAP 3014A 0 98 0 98 58CV A X 070 12 CAP 3614A 0 99 0 99 58CV A X 070 12 CNPH 3017A 0 99 0 99 58CV A X...

Page 26: ...100 20 CNPH 3617A 0 99 0 96 58MV B C 100 20 CNPV 3621A 0 99 0 96 58MV B C 100 20 CSPH 3012A 0 99 0 96 58MV B C 100 20 CSPH 3612A 1 01 0 97 58MV B C 100 20 CNPH 3017A 0 99 0 95 58MV B C 120 20 CNPH 36...

Page 27: ...0 98 1 09 CNPV 3617A 0 97 1 10 CNPV 3621A 0 97 1 10 CNPV 4217A 0 99 1 09 CNPV 4221A 0 98 1 09 CSPH 3612A 0 99 1 05 CSPH 4212A 1 00 1 06 CAP 3614A 0 96 1 02 58CV A X 070 12 CNPH 3617A 0 96 1 02 58CV A...

Page 28: ...1A 0 98 0 95 58MV B C 100 20 CSPH 3612A 0 99 1 00 58MV B C 100 20 CSPH 4212A 0 99 0 97 58MV B C 100 20 CAP 4224A 0 97 0 97 58MV B C 120 20 CNPH 3617A 0 96 0 98 58MV B C 120 20 CNPH 4221A 0 98 0 95 58M...

Page 29: ...NPV 4824A 1 00 1 13 CSPH 4212A 1 00 1 13 CSPH 4812A 1 00 1 13 CNPH 4221A 0 99 1 07 58CV A X 070 12 CNPH 4821A 1 00 1 08 58CV A X 070 12 CSPH 4212A 1 00 1 08 58CV A X 070 12 CSPH 4812A 1 00 1 08 58CV A...

Page 30: ...4221A 0 99 1 03 58MV B C 100 20 CNPV 4821A 1 00 1 04 58MV B C 100 20 CSPH 4212A 1 00 1 04 58MV B C 100 20 CSPH 4812A 1 00 1 04 58MV B C 100 20 CAP 4224A 0 98 1 06 58MV B C 120 20 CAP 4824A 1 00 1 04 5...

Page 31: ...0 96 1 00 58CV A X 090 16 CNPH 6024A 0 98 1 02 58CV A X 090 16 CSPH 4812A 0 97 1 01 58CV A X 090 16 CSPH 6012A 0 99 1 03 58CV A X 090 16 CAP 4821A 0 96 1 00 58CV A X 110 20 CAP 6021A 0 99 0 99 58CV A...

Page 32: ...CNPV 4821A 0 97 1 01 58PH 110 20 CSPH 4812A 0 97 1 01 58PH 110 20 CSPH 6012A 0 99 0 99 58PH 110 20 CAP 4824A 0 97 1 01 58PH 135 20 CAP 6024A 0 99 1 03 58PH 135 20 CNPH 4821A 0 97 1 01 58PH 135 20 CNPH...

Page 33: ...4 85 51 80 51 80 5 35 48 70 48 70 5 89 45 32 45 32 6 47 57 13 9 59 79 59 79 3 99 57 30 57 30 4 40 54 64 54 64 4 85 51 80 51 80 5 35 48 71 48 71 5 89 45 32 45 32 6 47 COOLING INDOOR MODEL CAPACITY POWE...

Page 34: ...5 73 5 27 1 18 7 70 7 07 1 23 9 77 8 91 1 29 12 01 10 66 1 35 14 50 13 20 1 42 17 32 17 32 1 51 20 39 20 39 1 61 23 82 23 82 1 74 675 5 83 5 36 1 18 7 81 7 18 1 23 9 91 9 03 1 28 12 16 10 80 1 33 14...

Page 35: ...V A X 090 16 CNPH 2417A 1 00 1 04 58CV A X 090 16 CNPH 3017A 0 98 1 02 58CV A X 090 16 CNPV 2417A 1 00 1 04 58CV A X 090 16 CNPV 3017A 0 98 1 02 58CV A X 090 16 CSPH 2412A 1 00 1 03 58CV A X 090 16 CS...

Page 36: ...CNPV 3017A 0 97 0 99 58CV A X 090 16 CNPV 3617A 0 97 0 99 58CV A X 090 16 CSPH 3012A 0 97 0 99 58CV A X 090 16 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CSPH 3612A 0 97 0 96 58CV A X 090 16 CA...

Page 37: ...0 99 58PH 070 16 CNPH 3017A 0 98 1 00 58PH 070 16 CNPH 3617A 0 98 1 00 58PH 070 16 CNPV 3017A 0 98 1 00 58PH 070 16 CNPV 3617A 0 98 1 00 58PH 070 16 CSPH 3012A 0 98 1 01 58PH 070 16 CSPH 3612A 0 99 0...

Page 38: ...90 16 CSPH 3612A 0 98 1 00 58CV A X 090 16 CSPH 4212A 0 98 0 99 58CV A X 090 16 CAP 3621A 0 97 1 02 58CV A X 110 20 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL CAP 4221A 0 98 1 01 58CV A X 110 2...

Page 39: ...3617A 0 99 1 07 58PH 045 08 CNPH 4221A 0 99 1 05 58PH 045 08 CSPH 3612A 1 00 1 03 58PH 045 08 CSPH 4212A 1 00 1 02 58PH 045 08 CAP 3617A 0 98 1 04 58PH 070 16 CNPH 3617A 0 98 1 06 58PH 070 16 CNPH 42...

Page 40: ...0 20 CNPH 4221A 0 99 1 05 58CV A X 110 20 CNPH 4821A 1 00 1 04 58CV A X 110 20 CNPV 4221A 0 99 1 05 58CV A X 110 20 CNPV 4821A 1 00 1 04 58CV A X 110 20 HEATING INDOOR MODEL CAPACITY POWER FURNACE MOD...

Page 41: ...20 CSPH 4212A 1 00 1 05 58MV B C 120 20 CSPH 4812A 1 00 1 04 58MV B C 120 20 CAP 4817A 1 00 1 05 58PH 070 16 CNPH 4221A 1 00 1 10 58PH 070 16 CNPH 4821A 1 00 1 05 58PH 070 16 CNPV 4217A 1 00 1 08 58PH...

Page 42: ...0 CSPH 6012A 0 97 1 03 58CV A X 110 20 CAP 4824A 0 97 1 05 58CV A X 135 22 CAP 6024A 0 97 1 03 58CV A X 135 22 CNPH 4821A 0 97 1 05 58CV A X 135 22 CNPH 6024A 0 97 1 03 58CV A X 135 22 CNPV 4824A 0 97...

Page 43: ...4 4 25 56 84 56 84 4 46 66 32 66 32 4 65 75 63 75 63 4 90 HEATING INDOOR MODEL CAPACITY POWER FURNACE MODEL FX4CN B F 060 1 00 1 00 FE4ANB006 1 00 1 00 FV4BNB006 1 00 1 00 FY4ANB060 1 02 1 07 CAP 6021...

Page 44: ...resistant Fan blades will be statically and dynamically balanced Condenser fan openings will be equipped with steel wire safety guards Compressor Compressor will be hermetically sealed Compressor will...

Reviews: