background image

 

 

 

OPERATING INSTRUCTION MANUAL 

FOR NARA ROTARY  VANE 2 STAGE VACUUM PUMPS, MOT-085  & MOT-140 

 
 

I

M PORTANT 

: THIS UNIT HAS BEEN DRAINED FOR SHIPMENT.   

DO NOT ATTEMPT TO OPERATE WITHOUT ADDING OIL.

 

 

 
 

 

 

 
 

** Dual  free  voltage  110V/220V  : You  may  select voltage  by changing  the switch  on the  rear  of vacuum  pump. 
              CAUTION

 

: 1. Try  to change  only  after disconnecting  of Pump  cord.  

2. Use standard  tools for this work . 

                                    3. Do  not try with  wet  hands

                                     

 
In  order  to  make  the  best  use  of  your  investment,  familiarize  yourself  with  the  new  features  and  operating 
instructions  before  starting  pump.  With  just  routine  care  your  Nara  vac uum  pump  will  give  you  years  of  reliable 
service  by following proper maintenance guidelines. Nara  vacuum  pump are  designed for  deep  vacuum  work in 
refrigeration  systems only. 
 
Each Nara  vacuum pump has been factory tested to guarantee  25 micron  or better and listed  CFM performance. 
The  serial  number  has  been  recorded.  Complet e  and  mail  the  Warranty  Registrat ion  card  within  10  days  of 
purchase  to validate  your  warranty.  You will  be notified  of  any technical updates.   
 
25,400  Microns = 1

” 

 
 

SPECIFICATION   

       

 

MOT-085 

MOT-140 

Note 

Pumping  speed 

50Hz 

70

/min,  2.5 CFM 

116

/min,  4  CFM 

 

60Hz 

85

/min,  3 CFM 

140

/min,  5  CFM 

 

Ultimate  vacuum 

pressure 

GB. Closed 

5 x 10

-3 

Torr 

 

GB. Open 

5 x 10

-2 

Torr 

 

Motor  speed 

50Hz 

1430  RPM 

 

60Hz 

1725  RPM 

 

Voltage/Hz 

Dual  voltage  110/220V,  Dual  cycle 50/60Hz 

 

 
 
 

Reviews: