background image

Wiring Diagram

24APA7

Performance

t

Series 2---Stage Air Conditioner

with Puron

r

Refrigerant

2 to 5 Nominal Tons

1.   Compressor furnished with inherent thermal protection.
2.   To be wired in accordance with National Electric Code (N.E.C.) and local codes.
3.   Outdoor unit control requires a minimum of 27 VA, 24 VAC control power.
4.   Use copper conductors only.  Use conductors suitable for at least 75ºC (167ºF).
5.   If indoor section has a transformer with a grounded secondary, connect the grounded 
      side to “C”.
6.   If any of the original wire, as supplied, must be replaced, use the same or equivalent wire.
7.   Check all electrical connections inside control box for tightness.
8.   Do not attempt to operate unit until service valves have been opened.
9.   In case of a communicating indoor system, 

 USE WITH INFINITY / EVOLUTION USER 

      INTERFACE AS LISTED IN PRE-SALE LITERATURE

.

10. In case of non-communicating indoor system disconnect factory provided wires from A, B, C,
      and D terminals.  Use factory provided wires to connect to Y1, R, C, and Y2 as required by
      Installation Instructions.  Cap or remove unused factory provided wires.
11.  For Communicating Control only.

CAP

CB

CCH
CHS

COMM

COMP

CAPACITOR 
CIRCUIT BOARD
CRANKCASE HEATER
CRANKCASE HEATER SWITCH
SYSTEM COMMUNICATION
COMPRESSOR

NOTES:

 * MAY BE  FIELD INSTALLED

LEGEND

FACTORY POWER WIRING

FACTORY CONTROL WIRING

FIELD CONTROL WIRING

FIELD POWER WIRING

COMPONENT CONNECTION

FIELD SPLICE

JUNCTION

 

CONT

CS

HPS

LPS
* LS

OAT
OCT

OFM

RVS
* SC
SEV
* SR

STATUS

TRAN

* UC

CONTACTOR
COMP HIGH CAP SOLENOID
HIGH PRESSURE SWITCH
LOW PRESSURE SWITCH
LIQUID SOLENOID
THERMISTOR (OUTDOOR AIR)
THERMISTOR COIL
OUTDOOR FAN MOTOR
REVERSING VALVE SOLENOID
START CAPACITOR
SOLENOID EXPANSION VALVE
START RELAY
SYSTEM FUNCTION LIGHT
TRANSFORMER
UTILITY CURTAILMENT

HPS

LPS

208/230 1Ø

POWER
SUPPLY

EQUIP  GND

L1

L2

RED/WHT

BRN/YEL

BLU

VIO

COMP

CCH

DEFROST

TIME

FORCED

DEFROST

2
3

C

RVS

QUIET

SHIFT

1

SEV

PL1

PL8

CB

VIO BLK RED

YEL

BRN

BLU

PWM2

PWM1

MODEL PLUG

LED

LED

COMM STATUS

120

60

30

30

60

TIME 
(MIN)

1

2

4

PL5

3

HI

LO

C

BRN/YEL

BLU

RED/WHT

1

PL4

3

SR

1

2

PL3

1

2

PL2

YEL/PNK

YEL/PNK

BLU/PNK

BLU/PNK

HPS

LPS

L1

ODF

CCH

L2

VR

VS

90

4

C

1

2

3
4
5

OCT

OAT

OCT

OAT

PL6

BRN

BRN

BLK

BLK

1

3

2

ON

OFF

(DEFAULT)

OCT

OAT

EQUIP

GND

T1

BRN

HI

LO

C

CONT

CS

TRAN 24V

T1

TRAN 230V

BLU

YEL

TRAN

24V

230V

CS

208V

COM

RED

RED

BRN

BLK

BLK

BLK

BLK

YEL

BLK

BLK

YEL

BLU

YEL

YEL

YEL

CONNECT TO

R AND Y2 ON

CONTROL BOARD

* UC (WITH INFINITY/EVOLUTION ONLY)

11 21

23 23

C C

CHS

BLU

YEL

*SC

BRN

*SR

1

2
5

BLK

 CAP

BLK

OFM

BRN

DEFROST

TIME

FORCED

DEFROST

2
3

C

RVS

QUIET

SHIFT

1

SEV

PL1

PL8

CB

PWM2

PWM1

MODEL PLUG

LED

LED

COMM STATUS

120

60

30

30

60

TIME 
(MIN)

1

2

4

PL5

3

1

PL4

3

SR

1

2

PL3

1

2

PL2

L1

CCH

L2

VR

VS

90

4

C

1

2

3
4
5

OCT

OAT

PL6

1

3

2

ON

OFF

(DEFAULT)

COMPONENT ARRANGEMENT

CONTACTOR

TRANSFORMER

CAPACITOR

CONTROL

BOARD

024
036
048

040
042
044

18
18
18

75

120
180

MODEL MODEL

PLUG

HK70EZ

SIZE

MODEL PLUG CHART

1 - 4 (R1)

2 - 3 (R2)

PIN RESISTANCE (K      )

060

046

18

270

H

C

F

*SC

*SR

1

2

5

L1

COMP

21

11

CONT

CCH

OFM

230V

C

CHS

CAP

H

C

F

CONT

L2

23

23

ODF

SCHEMATIC DIAGRAM  (LADDER FORM)

CONNECTION DIAGRAM

S

C

R

S

C

R

R C

Y1 Y2

W1

O

AS PROVIDED BY

MANUFACTURER

SEE NOTE #11

R C

Y1 Y2

W1

O

TO  INDOOR UNIT

A B C D

PL7

CONT

GRN

WHT

YEL

RED

R C

Y1 Y2

W1

O

AS PROVIDED BY

MANUFACTURER

SEE NOTE #11

A B C D

PL7

YEL

BLU

VIO BLK RED

YEL

BRN

BLU

YEL

BLU

OPTIONAL 

NON-COMMUNICATING 

CONTROL

SEE NOTE #10

    Short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of 

    the status code.  

UNIT OPERATION

This control board contains a five minute short cycle protector.  A five minute delay will 
occur between compressor OFF/ON cycles.  To bypass delay, short forced defrost pins 
for 1 second then release.  
The crankcase heater is energized during off cycle below 65ºF.

 

 

FAULT DEFINITION

 

 

 

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

FLASH CODE 

 

FAULT DEFINITION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLASH CODE 

On, No Flash

1, Pause
2, Pause
3, Pause
4, Pause
5, Pause
6, Pause

16
25
31
32
45
46

Standby
Low Stage
High Stage
ODU Fan Delay Defeat Not Active
ODU Fan Delay Defeat Active
Brown out is Disabled
Brown out is Active
System Communications Failure
Invalid Model Plug
High Pressure Switch Trip
Low Pressure Switch Trip
Control Fault
Brown out (230V)

47
53
55
56
71
72
73
74
81
82
83
84

No 230v with Call to Run
Outdoor Air Temp Sensor
Coil Temp Sensor
Temp Sensor Range Error
Low Stage Thermal Cutout
High Stage Thermal Cutout
Contactor Shorted
Contactor Open (No 230v to Comp)
Low Stage Thermal Lockout (4 HRS)
High Stage Thermal Lockout (4 HRS)
Low Pressure Lockout (4 HRS)
High Pressure Lockout (4 HRS)

TO  INDOOR UNIT

GRN

WHT

YEL

RED

337894-101  REV. B

Fig. 1 – Wiring Diagram — Model sizes 2 -- 5 tons, 208/230--1

Reviews: