Figure 1. Example of frosting eutectic plate

1. Stop the unit.
2. Open the cooling box doors.

The plates will defrost naturally.

The  defrosting  time  depends  on  the  frosting  and  also  the

ambiant temperature: 

keep the cooling box doors opened

from 3 to 12 hours according to the conditions

.

5. MAINTENANCE SCHEDULE

VATNA 200/300/400  Service frequency

Service Type

Period or

hours interval

12 month

24 months

Service A

X

X

Service B

X

6. RECOMMENDATIONS

This unit is not designed to carry special loads which emit

corrosive gas.

These kind of products can impact unit performance, and

seriously reduce component life time.

Please contact us if such products need to be carried.

• Perform a defrost of the eutectic plates at least once a week to ensure

an optimal efficiency of the eutectic system

Any excess of frosting lowers the efficiency of the eutectic

system.

• It is important to check the temperature of the product being loaded

to  ensure  that  it  is  at  the  correct  temperature  for  transport.  The

refrigeration unit is designed to maintain the temperature of the product

at the temperature at which it was loaded; it was not designed to cool

a warm product.

6.1. BEFORE LOADING

• Check the condition of the inside and outside of the insulated body, as

well as the door seals.

• Your vehicle should always be clean and well-aired.

6.2. WHEN LOADING

• To be carried out with the unit stopped.
• It is recommended to open doors as little as possible to avoid the intake

of hot air and humidity.

• Select the temperature by means of the thermostat, according to the

transported goods.

• Check  the  internal  temperature  of  the  goods  being  loaded  (using  a

probe thermometer).

• Leave a free space of about 6 to 8 cm between

load and front wall.

• Leave a free space of about 20 cm between

the top of the load and the roof.

• Load product on pallets (gratings) to provide

free air return to unit and improvement product

protection.

• Do not forget to close the doors.
• Before  closing  the  doors,  check  your  load  once  more  and  see  that

nobody is shut inside the box.

For stationary utilisation, we recommend to place the box in the

shade.

Never leave your unit more than a month without running.

Open the cooling box doors in case of extended stop.

7. RECOMMENDED TRANSPORT TEMPERA-

TURES

Below are some general recommendations on product transport temper-

atures and operating modes for the unit. These are included for reference

only and should not be considered pre-emptive of the Set-point required

by the shipper or receiver. More detailed information can be obtained from

your Carrier Transicold dealer.

PRODUCT

Temperature inside

the cooling box*

Ice

-20°C (-4°F)

Frozen fruits and vegetables

-18°C (-0°F)

Frozen meats and seafood

-20°C (-4°F)

Ice cream

-25°C (-13°F)

*  Given  by  the  Thermometer  that  indicates  the  temperature  inside  the

cooling box.

During delivery cycles that includes frequent stops and door

openings, it is recommended that the unit always be operated

in the continuous run mode to help insure product quality.

It is essential to shutdown the compartment during the periods

when the doors are open, in order to maintain the temperature

of  the  cargo  in  the  other  compartments  and  keep  the  unit

operating correctly.

62-61954-01

4

Summary of Contents for VATNA 200

Page 1: ... precaution 2 3 2 Risks 2 3 3 Warning Stickers Maintenance 2 4 OPERATION 2 4 1 Control box description 2 4 2 Start the unit on standby 3 4 3 Stop the unit 3 4 4 Defrost the unit 3 5 Maintenance Schedule 4 6 RECOMMENDATIONS 4 6 1 Before loading 4 6 2 When loading 4 7 RECOMMENDED TRANSPORT TEMPERATURES 4 8 A T P EUROPE REGULATION EXTRACT 5 9 24H ASSISTANCE 5 62 61954 01 1 ...

Page 2: ...f the model and Serial Number B before calling for assistance This information will be needed when you contact a technician so that he may properly assist you The sticker C indicates the noise level in Lwa sound power level 2 2 NOISE LEVEL CHARTS Unit Maximum Sound Power level LWA dB VATNA 200 300 400 54 3 SAFETY 3 1 WARNING AND PRECAUTION This manual contains safety and service instructions to fo...

Page 3: ... the power plug Reverse the red part by using a screw driver In the event of difficulty on start up check that Network supply is Ok Overload relay is not open by pushing the red REARM button 4 2 1 STANDBY GUIDELINE Standardized exten sion cable H 07 RNF mm 2 Unit Fuse 220 3 50Hz Fuse 400 3 50Hz 220 volts 400 volts VATNA 200 15 A 12 A 4 x 2 5 mm 4 x 2 5 mm VATNA 300 20 A 15 A 4 x 4 mm 4 x 2 5 mm VA...

Page 4: ...perature by means of the thermostat according to the transported goods Check the internal temperature of the goods being loaded using a probe thermometer Leave a free space of about 6 to 8 cm between load and front wall Leave a free space of about 20 cm between the top of the load and the roof Load product on pallets gratings to provide free air return to unit and improvement product protection Do...

Page 5: ...ve an insulated unit approved as a refrigeration unit an application to modify the approval certificate should be sent to the regional health office 9 24H ASSISTANCE At Carrier Transicold we re working hard to give you complete service when and where you need it That implies a worldwide network of dealers and available an emergency service These service centres are manned by factory trained servic...