MODEL 62 ACCU-CRIMP
OPERATING INSTRUCTIONS
APPLICATION
The Model 62 Accu-Crimp is a portable bench top pneumatic crimper designed to crimp loose
terminals on to Discrete wire, Coaxial and Flat Modular Telecommunications cable.
AIR REQUIREMENTS
80-100 P.S.I., ***
CLEAN AND DRY.***
DIE SET INSTALLATION
STANDARD SINGLE RETAINING SCREW TYPE
1.
Disconnect air line from air source.
2.
Remove (2) Screws
#8716
from Top Jaw Assembly
#8701
and Bottom Jaw
#8706.
3.
Press down and hold Knob
#8710
on top of crimper and insert die set.
4.
Release Knob and re-install (2) Screws
#8716
into Jaw Assemblies.
5.
Reconnect air line.
Note: Reverse procedure for die set removal.
AMP DUAL PIN DIE SET WITH RETAINING SCREW
1.
Disconnect air line from air source.
2.
Remove locator assembly, die set and 4 die retaining pins from AMP hand tool.
3.
Remove (2) Screws
#8716
from Top Jaw Assembly
#8701
and Bottom Jaw
#8706.
4.
Press down and hold Knob
#8710
on top of crimper. Insert upper die set(chamfer side out), 2
retaining pins and Screw
#7214
. Slide locator assembly through screw and secure with acorn
nut from hand tool.
5.
Press down and hold Knob
#8710
on top of crimper. Insert lower die set(chamfer side out),
2 retaining pins and secure with Screw
#8724
.
6.
Reconnect air line.
Note: Reverse procedure for die set removal.
OPERATION
1.
Press down on Knob
#8710,
insert terminal into die set and release Knob.
2.
Insert wire into terminal.
3.
Activate foot pedal switch.
4.
Press down on Knob and remove crimped wire.
Some applications may require you to install the terminal on to the wire first, then follow
steps 1, 3 and 4.
Coaxial connectors may require two separate crimping operations on the same wire.
Check the instructions supplied with terminal connectors and follow the required steps
needed.