background image

R

IS1132A(07/11)

(SIDE 1 OF 2)

Fig. 1

1

2

3

4

9

10

11

12

15

17

16

14

Inlet Connection End

13

Mixer Connection End

Deck

5

6

7

8

18

19

20

21

22

Spigot

Important Information

3)

4)Flexible Tail Inlet Connections: Connect the flexible tails (16)

to the hot and cold isolating stop taps, hand tighten the

connecting nut (15) until rubber cone contacts the sealing

face of the connection end, then tighten a further one turn 

to provide a watertight joint.

Important: Flexible tails must not be kinked, twisted or in

tension when installed. (Minimum Bend Radius:- 50mm)

Do not install flexible tails where subject to ultra violet light.

Insert the inlet connection end (15) of each flexible tail (16)

through the hole in the deck. Place mixer over deck hole, fit

gasket (11) and fixing plate (12) over stud (13) then screw

on fixing nut (14). Position mixer as shown, ensure 

caroma

marking on base ring (9) is facing towards the front, then 

tighten fixing nut (14) using a suitable spanner.

All pipework must be thoroughly flushed prior to

installation, as foreign materials may block the

flow regulating device and reduce the flow of water.

Note: Aerator insert housing must be retightened

to prevent removal by hand.

*

Isolating stop taps must be fitted to the hot & cold water

supply connections. (Part No. 842018C - Mini cistern 1/4T)

*

*

* Not suitable for gravity feed systems.

Mixer is fitted with a 7.6 L/min flow regulated aerator insert.

If swivel spout (22) is required to be fitted, first place retainer 

(18) in spigot groove (19). Ensure 'O' rings are well lubricated 

then slide the swivel spout (22) over spigot, taking care that 

the hole in the swivel spout (22) aligns with the retainer hole.

Fit screw (20) and tighten with 2mm allen key (21) provided.

5)

2) Flexible Tail Mixer Connections: Apply suitable lubricant to

'O'rings (17). Fit flexible tail (16) (with red indication) into

hole marked with a Red Dot in underside of mixer body (8).

Hand tighten the tail, ensuring the 'O'ring (17) has fully

entered the sealing bore to provide a watertight joint. Fit

other flexible tail (with blue indication) into remaining hole

in a similar manner.

1) From fixing pack fit 'O'ring (10) into groove in base ring (9).

Screw stud (13) into underside of mixer body (8). Locate 

spigot of base ring (9) into base of mixer body (8).

Laundry Mixer Installation

PLUMBERS INSTALLATION INSTRUCTIONS

CIRRUS - LAUNDRY MIXER SET

WATER EFFICIENT TAPWARE

(NOMINAL FLOW RATE = 7 L/min)

Replacing Cartridge

Turn off hot and cold water supplies.
Carefully remove plug (4) before using a 2.5mm allen 

key (3) to loosen grub screw (2) and remove handle (1). 

Remove cap (5) taking care not to damage the decorative 

finish. Unscrew nut (6) then lift out old cartridge (7).
Ensure inside face of mixer body (8) is clean. Check that

seal (21) is in position in base of new cartridge (7). Fit new 

cartridge (7) into mixer body (8), taking care that two lugs

on base of cartridge (7) fit into mating holes in mixer body (8).
Screw on nut (6). 

Important: Nut (6) should be tightened 

to a torque of 10 Nm.
Replace cap (5), tightening by hand. Fit handle (1) taking 

care that it is pushed fully down, then tighten grub 

screw (2). Replace plug (4) taking care not to damage 

the decorative finish.
Turn on water supplies and check operation.

1)
2)

3)

4)

5)

6)

Hot and cold water inlet pressures should be equal.
Static inlet pressure range : 150-1000 kPa

IMPORTANT

Pressure & Temperature Requirements.

Deck thickness : 45mm maximum

Deck Requirements

Maximum hot water temperature : 80 C.

Tap body hole (in deck) :  34-36mm

New Regulation:- 500 kPa maximum static pressure

at any outlet within a building.

(Ref. AS/NZS 3500.1-2003, Clause 3.3.4)

Reviews: