See Fig. 1 for a description of the model number.
DISCHARGE CHECK VALVE
The discharge check valve is an axial movement type located

within the compressor. The check valve is field serviceable by re-

moving the oil separator or discharge line to access the valve in

the compressor discharge housing.
COMPRESSOR MOTOR
The 06Z compressor has one standard motor offering

a 2-pole in-

duction motor for improved compressor efficiency.
INTEGRATED DISCHARGE MUFFLER
The 06Z compressor is equipped with an integrated discharge

muffler specifically designed to reduce discharge gas pulsation

and resonance, resulting in reduced refrigerant line vibration and a

quieter refrigeration system.

PRESSURE RELIEF VALVE
The 06Z screw compressors have an internal relief device, which

is designed to relieve pressure from the high side to the low side

of the compressor.
SUCTION AND ECONOMIZER SCREENS
To increase the reliability of the compressor, a screen has been

incorporated as a standard feature into the suction inlet and econ-

omizer inlet of the compressor. The suction inlet screen is in-

stalled into the suction inlet of each compressor. The economizer

inlet screen is supplied in the economizer flange package (which

is included in the compressor component kit. Please refer to the

economizer flange installation instruction document for more

details.
CAPACITY CONTROL
All 06Z screw compressors are VFD capable as defined in Table 1

and do not utilize a slide valve unloading system. The compressor

capacity may be varied continuously to a lower limit of 22% of the

economized compressor’s full load capacity for air-cooled

applications.
VI CONTROL
All 06Z models are supplied with a Vi control valve which func-

tions to maintain optimum compressor efficiency. The Vi control

valve setting is variable and is actuated by the Carlyle PCM mod-

ule, which continuously monitors the operating pressures and con-

trols the Vi output accordingly. Depending on the operating condi-

tion and drive frequency, the compressor will run more efficiently

with either the Vi control valve engaged or disengaged.

Fig. 1 — Model Number Nomenclature

Table 1 — Variable Speed Screw Compressor 

Offering

MODEL NUMBER

NOMINAL

HP

VOLTS/

HERTZ

SPEED

RANGE

MOTOR

TYPE

06ZCE1H3AA06013

130

460V - 100 Hz

25 - 105 

Hz

2-pole

Induction

06ZCE1T3AA06013

380V - 100 Hz

06ZCE1Y6AA06013

200V - 100 Hz

06ZFC2H3AA06013

215

460V - 98 Hz

25 - 98 Hz

06ZFC2T3AA06013

380V - 98 Hz

06ZFC2Y6AA06013

200V - 98 Hz

06ZJG3H3AA06013

325

460V - 95 Hz

25 - 95 Hz

06ZJG3T3AA06013

380V - 95 Hz

06Z F C 2 H 3 A A 0 6 0 1 3

Compressor Family
06Z

 – VFD Screw Compressor

Frame Size Group
C

 – Frame 1 - 139 MM

F

 – Frame 2 - 168 MM

– Frame 3 - 199 MM

Outlet Case Group
C

 – 2.7 Axial Vi

E

 – 2.85 Axial Vi

G

 – 3.0 Axial Vi

Motor Group – HP and Type
1

 – 130 HP Induction Motor

2

 – 215 HP Induction Motor

3

 – 325 HP Induction Motor

Motor Group – Voltage
H

 – 460 VAC

T

 – 380 VAC

Y

 – 200 VAC

Rotor Case Group
3

 – 3 Terminal Pins

6

 – 6 Terminal Pins

Nameplate Group
A

 – Internal Use

Discharge Group
A

 – Integral Muffler

B

 – Standard Discharge

Accessory Group
0

 – No Accessories

Paint Group
6

 – Grey

Future Group
0

 – Not Used

Mounting Feet Group

1

 – Bar Feet - 500 MM

Packing Group
0

 – No Packaging

1

 – Returnable

3

 – Wood

4

 – Multi-pack

5

 – Service/Air Freight 

Summary of Contents for 06ZCE1H3AA06013

Page 1: ...J Carlyle offers distinct versions of the vari able screw compressor for Medium High Temperature applica tions qualified with R 134a R 1234ze or R 513A refrigerants The following compressor features a...

Page 2: ...capacity may be varied continuously to a lower limit of 22 of the economized compressor s full load capacity for air cooled applications VI CONTROL All 06Z models are supplied with a Vi control valve...

Page 3: ...3 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1...

Page 4: ...4 Fig 2 Compressor Physical Data and Connections 06ZC Frame 1 cont...

Page 5: ...5 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2...

Page 6: ...6 Fig 3 Compressor Physical Data and Connections 06ZF Frame 2 cont...

Page 7: ...7 Fig 4 Compressor Physical Data and Connections 06ZJ Frame 3...

Page 8: ...ISO 220 ASSEMBLY GREASE On occasion it may be necessary to use an assembly grease to re tain an O ring within its groove The following assembly grease is approved for use with the 06Z screwcompressor...

Page 9: ...Reverse rotation is most likely to occur at initial start up or whenever the wiring to the compressor terminals is disturbed To minimize the possibility for reverse rotation operation Carlyle recommen...

Page 10: ...Module package P N 6BSB000929 which provides the follow ing safety control functionality Discharge Temperature Monitoring Oil Level Monitoring Oil Flow Rate Supply Monitoring Table 3 Control Points S...

Page 11: ...he a 500 watt flexible strip heater is recommended The heater should be wired to oper ate when the compressor is OFF This minimizes the migration of refrigerant to the oil stored in the sump Figure 6...

Page 12: ...ith the following protocol networks BACnet1 Modbus2 N2 Open LonWorks3 requires optional card RS485 Communication Port If applying the Carlyle PCM module the accessories listed in Ta ble 5 are required...

Page 13: ...13 PCM INPUTS OUTPUTS See Fig 9 for descriptions of the PCM Inputs and Outputs Fig 9 PCM Inputs and Outputs...

Page 14: ...ssor off Motor Temperature Tm will have the following functions Control a motor cooling valve to provide liquid injection to the motor compartment Turn the compressor off on an overheated motor temper...

Page 15: ...ON LED INDICATION OUTPUT 4 OUTPUT 5 COMPRESSOR MANUAL RESET REQUIRED HIGH DISCHARGE TEMPERATURE TRIP Solid red Opens De energized OFF Yes HIGH MOTOR TEMPERATURE TRIP Constant blinking Opens De energiz...

Page 16: ...ERATURE 1 Compressor must be forced to Nominal Voltage as stated in Compressor Input Voltage 2 If operating at max speed reducing speed will allow motor to run on the rated V F curve if motor temperat...

Page 17: ...17 Fig 13 Compressor Connection Details Fig 14 Sample Compressor Motor Voltage Curves...

Page 18: ...95 Hz 25 Hz 98 Hz 618 787 865 380V 3 95 Hz 25 Hz 98 Hz 325 414 455 460V 3 95 Hz 25 Hz 98 Hz 269 342 377 06ZJ 325 Hp 380V 3 95 Hz 25 Hz 98 Hz 566 720 792 460V 3 95 Hz 25 Hz 98 Hz 468 596 655 Table 13 A...

Page 19: ...of the compressor motor The thermistors are an NTC type with a standard resistance of 5000 ohms at 77 F 25 C All 06Z compressor motors are supplied with a spare thermistor to be used if the primary th...

Page 20: ...GPM 06ZC 30XV50092301 Vertical 3 125 7 06ZF 30XV50122601 Vertical 4 125 7 06ZJ 30XV80004301 Horizontal 4 50 8 Table 19 Accessory Package PART NUMBER COMPRESSOR USAGE 06ZC 06ZF 06ZJ 06ZC660001 X 06ZF66...

Page 21: ...store the compressors in doors where they are shielded from the weather Outdoor storage is permissible as long as temperatures stay within a temperature range of 40 F to 176 F 40 C to 80 C Weights an...

Page 22: ......

Page 23: ......

Page 24: ...and without incurring obligations CARLYLE COMPRESSOR DIVISION 2022 Carrier P O Box 4808 Syracuse New York 13221 Phone 1 800 532 5031 Fax 1 315 432 3274 In U S and Puerto Rico 1 800 GO CARLYLE 1 800 46...

Reviews: