Warning: Never power up a unit without proper cabling and attenuation. You must have at least
60 dB of attenuation between RuralConnect® units. Failure to do so could result in system
damage that may void the warranty.
2.9.1.
Test Cable Set
The bench-testing cable set (“RC-TECH-KIT”) will allow you to
bench test a Basestation with two CPEs. Connect the units with
the supplied cables and connectors. This consists of a set of
coax jumper cables (one for each unit), an F-type splitter and
five 19 dB attenuators (one for the Basestation, two for each
CPE).
2.9.2.
Setting up the Bench
Use the supplied yellow Ethernet patch cable to connect the
radio’s Ethernet port to the Base controller board Ethernet port
as shown in Figure 4.
For Internet access, connect the Basestation unit to a DHCP-
enabled network via a standard Ethernet cable. Plug the
Ethernet cable into the Ethernet port nearest to the power jack.
Figure 3: Bench-Testing Cable Set
Note the blue cable in
tation
Ethernet
Figure 5 as an example:
Connect the Bases
unit’s power supply to its
barrel-type power jack, as
shown in photo.
Using a standard
cable (not supplied),
connect each CPE unit to
the “Out” connection of a
POE injector as shown
below:
Figure 4: Basestation with Ethernet cable connected
Connect each unit to a power source.
Wait approximately 3-5 minutes for the system to
initialize.
Figure 5: Basestation Connections
Figure 6: POE Injector Connections