METER / PIPE 

SIZE 

MODEL 

*CONTINUOUS 

FLOW 

FLOW 

RANGE 

LENGTH

 

HEIGHT

 

WIDTH

 

CONNECTION 

LENGTH (X2) 

⅝” X ¾

750MRS 

10 GPM 

¼

 - 20 GPM 

7

½”

 

4

¼

 

3

⅝”

 

2” 

¾

" X 

¾

7575MRS 

15 GPM 

½ - 30 GPM 

7

½”

 

4

” 

3

⅞”

 

2” 

1" 

1000MRS 

25 GPM 

¾

 - 50 GPM 

10

¼

 

4

½

 

4” 

2

¼

” 

1

½

150MRS 

50 GPM 

1

½

-100 GPM 

11

⅞”

 

6” 

5” 

2

” 

2" 

200MRS 

80 GPM 

2 - 160 GPM 

11

⅞”

 

7” 

6

½”

 

2

¾

” 

METER / PIPE 

SIZE

 

MODEL

 

0.1 

GPC 

1      

GPC 

10     

GPC 

100 

GPC 

LPC 

10 

LPC 

100 

LPC 

1000 

LPC 

 

” X 

¾

750MRS 

X  

X  

X  

X  

X  

X  

X  

X  

¾

" X 

¾

7575MRS 

X  

X  

X  

X  

X  

X  

1" 

1000MRS 

X  

X  

X  

N/A

 

X  

X  

X  

1

½

150MRS 

N/A

 

X  

X  

X  

N/A

 

X  

X  

X  

2" 

200MRS 

N/A

 

X  

X  

X  

N/A

 

X  

X  

X  

X = AVAILABLE CONTACT SETTINGS 

(All contact settings are pre-set at the factory to your specification 

– call for available Cubic Feet contact settings.) 

 

 

MRS

®

 METER SPECIFICATIONS

 

METER SELECTION CHART 

 

Warranty: 

Carlon Meter, Inc. warrants its products to be free of defect in material or workmanship for a period of twelve months 

from the date of purchase. Contact us to obtain a copy of our complete statement of warranty. 

Helpful Hints: 

1. Install a Carlon Slow-Closing Valve downstream of your water meter.  This will eliminate possible meter damage 
     from water hammer in your system. 
2. Install a Carlon Strainer upstream of your water meter to protect the meter and any other in-line process equipment 
     from becoming jammed by particulate matter in your system. 

Reed Switch:    

 Dry contact type, normally open, 24V, 100mA maximum 

Pressure Rating: 

 

Maximum 150 psi. 

Temperature Range:   

35° - 122°F.  Protect the meter from freezing. 

PH Level Range: 

 

6.5 

– 8.0

  

Accuracy:   

 

 

+/- 1.5% of maximum flow when operating between minimum and maximum flow range. 

Register Options: 

 

U.S. Gallons, Liters 

(consult factory regarding Cubic Feet register options).

 

Installation Instructions: 

1.

 

Flush the line thoroughly after all plumbing changes to prevent contaminates from entering the meter. 

2.

 

Install horizontally with the register facing up and inlet port facing the water supply line.  

3.

 

For outdoor installation, protect meter from direct exposure to the elements. 

4.

 

Protect meter from backflow of water opposite of indicted flow direction. 

*Continuous Flow: 

The size of meter selected should be based upon continuous flow, GPM, as opposed to pipe size. 

 For example, if it is determined that continuous flow is 25 GPM, a 

1“ meter should be selected rather than a 

¾

“ meter. 

ORDERING INFORMATION: 

Specify model number shown followed by choice of contact pulse setting desired.  

Add a 

G

 for Gallon reading or an

 L

 for Liters reading or a 

C

 for Cubic Feet reading. 

Example: 1

½

" meter with gallon register and 10 gallons per contact = 150MRS-10 GPC. 

GPC = Gallons Per Contact     

      LPC = Liters Per Contact     

     CFPC = Cubic Feet Per Contact 

(Available upon request)

 