background image

&RQ¿JXUHWKHV\VWHP

EM24 E1 - Instruction manual | CARLO GAVAZZI Controls SpA

Settings from EM24 E1

General settings

7KHDYDLODEOHVHWWLQJVGHSHQGRQWKHDSSOLFDWLRQVHW

Page title

Sub-menu

Description

Values

Default value

Cng PASS

-

Change password

From 0 to 9999

0

APPLiCAt

Application

tYP.A
tYP.b
tYP.C
tYP.d
tYP.E
tYP.F
tYP.G
tYP.H

tYP.H

User

USEr 1

User

From 0 to 9999

1

USEr 2

From 0 to 9999

2

USEr 3

From 0 to 9999

3

dHCP

-

DHCP enabling

oFF/on

oFF

IP Addr

IP  o.-.-.-

IP address

From 000 to 255

192

IP  -.o.-.-

From 000 to 255

168

IP  -.-.o.-

From 000 to 255

1

IP  -.-.-.o

From 000 to 255

10

SUb

SUb  o.-.-.-

Subnet mask

From 000 to 255

255

SUb  -.o.-.-

From 000 to 255

255

SUb  -.-.o.-

From 000 to 255

255

SUb  -.-.-.o

From 000 to 255

0

GAtE

GAtE  o.-.-.-

Default gateway

From 000 to 255

192

GAtE  -.o.-.-

From 000 to 255

168

GAtE  -.-.o.-

From 000 to 255

1

GAtE  -.-.-.o

From 000 to 255

1

Port

-

MODBUS TCP port

502

SELECtor

SELEC. 1

Page displayed according to selector 
position among the available pages for 
each application (see”Frontal selector” 
on page 15)

From 1 to 28

1

SELEC. 2

From 1 to 28

25

SELEC. 3

From 1 to 28

28

SELEC.LoC

From 1 to 28

3

SYS

-

System

3P.n
3P.1
2P
1P
3P

Note:

 MID (PFA, PFB): only 3P.n

3P.n

Ut rAtio

-

Voltage transformer ratio (VT)

AV5: from 1 to 6975
AV2: N/A

1

Ct rAtio

-

Current transformer ratio (CT)

AV5: from 1 to 6975
AV2: N/A

1

P int.ti

-

Dmd integration time (min)

From 1 to 30

15

FiLtEr.S

-

,QWHUYDORI¿OWHULQWHUYHQWLRQZLWKUHVSHFW

to full scale (%)

From 0 to 100

2

FiLtEr.Co

-

)LOWHUFRHI¿FLHQW

From 1 to 32

2

End

-

Exit and save

-

-

Note:

 the 

Ut rAtio

 is available for compatibility with other versions, even though the AV5 version is not meant to be used with voltage transformers. It should 

be therefore set to 1.

Summary of Contents for EM24 E1

Page 1: ...EM24 E1 USER MANUAL MANUALE UTENTE BETRIEBSANLEITUNG MANUEL D EMPLOI INSTRUCCIONES DE USO BRUGERMANUAL EN IT DA ES FR DE...

Page 2: ...EM24 E1 Three phase energy analyzer USER MANUAL...

Page 3: ...QHWZRUN SDUDPHWHUV ZLWKRXW 3 Working with EM24 E1 7 RUNLQJ ZLWK WKH PHDVXUHPHQW LQIR PHQX RUNLQJ ZLWK WKH VHWWLQJV PHQX 5HVHWWLQJ SDUWLDO HQHUJ PHWHU 6HWWLQJ D SDUDPHWHU Menu description 9 0HDVXUHPHQ...

Page 4: ...DQ LQWHJUDO SDUW RI WKH SURGXFW DQG DFFRPSDQLHV LW IRU LWV HQWLUH ZRUNLQJ OLIH W VKRXOG EH FRQVXOWHG IRU DOO VLWXDWLRQV WLHG WR FRQILJXUDWLRQ XVH DQG PDLQWHQDQFH RU WKLV UHDVRQ LW VKRXOG DOZD V EH DFF...

Page 5: ...G WKH FRPPLVVLRQLQJ DQG DOO WKH FRQILJXUDWLRQ SDUDPHWHUV FDQ EH VHW XS YLD 8 6 Description AV2 AV5 Part Description A LCD display B 9ROWDJH FXUUHQW FRQQHFWLRQV C R VWLFN D 6HOHFWRU ZLWK SLQ IRU 0 VHDO...

Page 6: ...ay is divided into 3 lines Symbol Description LVSOD LQJ RI SKDVH WR QHXWUDO V VWHP YROWDJH LVSOD LQJ RI SKDVH WR SKDVH V VWHP YROWDJH LVSOD LQJ RI PD YDOXHV User ID LVSOD LQJ RI V VWHP YDULDEOHV LVSOD...

Page 7: ...TXLUHG QHWZRUN SDUDPHWHUV DVVLJQHG E QHWZRUN DGPLQLVWUDWRU Setting network parameters without DHCP Step Action QVWDOO 0 LVDEOH 3 GHIDXOW VHWWLQJ 3 RQQHFW WKH 3 WR WKH 0 YLD WKHUQHW FDEOH SRLQW WR SRLQ...

Page 8: ...ing partial energy meter Step Action Button 3UHVV WKH EXWWRQ IRU DW OHDVW VHFRQGV In the PASS SDJH VHW WKH SDVVZRUG 1357 3 RQILUP RSHUDWLRQ 4 In the rESEt SDJH VHW YES 5 RQILUP RSHUDWLRQ to next measu...

Page 9: ...g a parameter Example procedure how to set Ct rAtio 20 and save changes Step Action Button 3RZHU RQ WKH HQHUJ DQDO HU 3UHVV WKH MR VWLFN IRU DW OHDVW VHFRQGV 3 In the PASS SDJH VHOHFW WKH FRUUHFW SDVV...

Page 10: ...QW SRZHU 3DUWLDO UHDFWLYH HQHUJ N K W W GPG PSRUWHG DFWLYH HQHUJ WDULII 6 VWHP DFWLYH SRZHU GPG N K W W GPG PSRUWHG DFWLYH HQHUJ WDULII 6 VWHP DFWLYH SRZHU GPG N K t3 W GPG PSRUWHG DFWLYH HQHUJ WDULII...

Page 11: ...H FXUUHQW 3KDVH FXUUHQW 3KDVH FXUUHQW 9 9 9 3KDVH SKDVH YROWDJH 3KDVH SKDVH YROWDJH 3KDVH SKDVH YROWDJH 9 9 9 3KDVH YROWDJH 3KDVH YROWDJH 3KDVH YROWDJH Note in programming mode the last displayed page...

Page 12: ...000 to 255 192 GAtE o From 000 to 255 168 GAtE o From 000 to 255 1 GAtE o From 000 to 255 1 Port MODBUS TCP port 502 SELECtor SELEC 1 Page displayed according to selector position among the available...

Page 13: ...neutral voltage IUHTXHQF WRWDO LPSRUWHG DFWLYH HQHUJ DFWLYH SRZHU GPG DQG GPG PD WRWDO LPSRUWHG UHDFWLYH HQHUJ DSSDUHQW SRZHU GPG DQG GPG PD 6 C 6 VWHP SKDVH VHTXHQFH phase neutral voltage IUHTXHQF WR...

Page 14: ...voltages 6 6 VWHP SKDVH VHTXHQFH phase neutral voltage IUHTXHQF WRWDO LPSRUWHG DQG H SRUWHG DFWLYH HQHUJ DFWLYH SRZHU GPG DQG GPG PD phase phase voltage active energy PD LPXP GPG FXUUHQW partial acti...

Page 15: ...XH LQ WKH 1201Fh register Frontal LED and selector Frontal LED The frontal red LED flashes proportionally to the active imported energy consumption if the selector is in 1 2 position and to the reacti...

Page 16: ...FORWK WR FOHDQ WKH GLVSOD R QRW XVH DEUDVLYHV RU VROYHQWV Responsibility for disposal 7KH SURGXFW PXVW EH GLVSRVHG RI DW WKH UHODWLYH UHF FOLQJ FHQWHUV VSHFLILHG E WKH JRYHUQPHQW RU ORFDO SXEOLF DXWKR...

Page 17: ...EM24 E1 8VHU PDQXDO _ RS ULJKW CARLO GAVAZZI Controls SpA YLD 6DIIRU H HOOXQR WDO ZZZ JDYD LDXWRPDWLRQ FRP LQIR JDYD L DXWRPDWLRQ FRP LQIR ID...