Carlisle Machine Works Lucio Instruction Sheet Download Page 2

Control Valves: 

 
Standard models require two valves which are, located on the back of the Lucio Burner.  One control 
valve has a red handle and is used for metering the fuel gas flow to the burner.  One control valve has a 
green handle and is used for metering the oxygen flow to of the burner.   
 
These control valves are finely threaded and thus require several full turns to become fully open or fully 
closed.  When using these valves to control the flames, it is best to make small incremental adjustments 
rather than full turns.  Quick or large adjustments could cause the flame to become unstable and even 
blow off of the face of the burner.   In time, the  user will learn the best  way to control the burner for 
their application. 
 
The valve stems are threaded and secured into the valve body via a nut.  This nut is threaded onto the 
valve body and the stainless steel stem extends through this nut.  Depending on how tightly this nut is 
threaded down onto the valve body, the stainless steel stem will be harder or easier to turn.  If the nut is 
tightly  threaded  down  onto  the  valve  body,  the  stem  will  have  more  resistance  to  movement.    By 
loosening this nut, the stem will become easier to adjust.  Loosening the nut can also cause a leak to 
form around the stem from the nut sealing area.  Be sure to check for leaks (see 

“Checking for Leaks”

anytime that this nut is adjusted. 
 

When  closing  the  control  valve,  the  valve  should  be  adjusted  only  until  it  seats  and  stops 
turning.    The  valve  should  not  be  forced  or  “torqued”  down  any  further.

  By turning the valve 

handle with force, beyond its seal positioning,  once it has seated, great pressure may be placed on the 
seat.  This will cause the seat or valve stem to become deformed and will result in a leak that can not be 

Carlisle Machine Works, Inc.,  

P.O. Box 746, 412 S. Wade Blvd., Bldg. #5, Millville, NJ  08332  

Toll Free Phone :  (800) 922 - 1167   

Local Phone : (800) 825 - 0627       

Fax:  (856) 825 - 5510  

     Website:   carlislemachine.com        Email:   [email protected]  

Lucio Burner Instruction Sheet 

Lucio  Instructions-1 

Checking for Leaks:  

 
Before operating the Lucio Burner for the first time and once a month (see 

“Maintenance”

) the burner 

should have the control valves and all connections checked for leaks.  Follow the procedure below to 
check for leaks. 
 
1.  Connect air at 25 PSI to the burner. 
2.  Dip the head of the burner into a bucket of water. 
3.   Cycle through the control valves turning each one on and then shutting it  off.  When the control 

valve is opened there should be a rush of bubbles in the water.  After shutting the control valve off, 
wait  about  30  seconds  to  watch  for  any  new  bubbles.    If  bubbles  appear  at  any  rate,  this  would 
indicate a leak in the control valve. 

4.   Remove the head from the water and use the air pressure to blow out any residual water. 
5.  Mix soap (liquid soap is best for this) and water to form a bubbly mixture for leak detection. 
6.  Turn on both control valves. 
7.  Apply  the  soapy  mixture  to  all  threaded  connections,  valve  stems  and  between  the  barrel  and 

manifold at the back of the burner.  If any of these areas produces bubbles after applying the soapy 
mixture, the connection may have a leak. 

8.  Close all control valves and disconnect the air. 

If a leak is detected, contact a Carlisle Representative for assistance. 