Function Menu
Dynacode II IP
62
Operating Manual
03.21
10.5 Machine Parameters (Intermittent Mode)
Number of pieces:
A print order with a defined number of pieces is transferred. After the
generating process the target number and the actual number of
pieces is shown in the display. A cycle is started via signal input 1.
With each cycle the actual number of pieces is increased by the
number of printed layouts. In case the target number of pieces is
reached the print order is finished and the display shows again the
main menu.
Continuous:
A print order is transferred. After the generating process the number
of printed layouts is shown in the display. A cycle is started via signal
input 1. With each cycle the number of printed layouts is increased.
The print order is active as long as it is terminated by the user or in
case of new data transmission.
Test mode:
This operating mode corresponds to mode 2. After the return of the
print unit to the zero point of the machine, however, internally a further
cycle is started (endurance test).
Direct start:
A print order is transferred. After termination of generating process the
print order is executed without an external signal.
Indication of back speed of print mechanics after print end in mm/s.
Each cycle of the machine consists of printing and return to the zero
point of machine. The print speed and back speed can be set
separately.
Because of this value you can select for low machine clock cycles an
operating method which saves the material and increases in this way
the life of the printhead.
Because of the mass moment of inertia, it could be better to reduce
the speed at an installation position of the print unit at >30° horizontal.
Value range: 50 … 600 mm/s.
Operating mode
Back speed
Summary of Contents for Dynacode II IP107
Page 1: ...DYNACODE II IP Ingress Protection Version Operating Manual...
Page 6: ...Table of Contents Dynacode II IP 6 Operating Manual 03 21...
Page 10: ...Introduction Dynacode II IP 10 Operating Manual 03 21...
Page 16: ...Intermittent Mode Dynacode II IP 16 Operating Manual 03 21...
Page 20: ...Operating Conditions Dynacode II IP 20 Operating Manual 03 21...
Page 46: ...Load Transfer Ribbon Cassette Dynacode II IP 46 Operating Manual 03 21...
Page 124: ...Touch Screen Display Dynacode II IP 124 Operating Manual 03 21...
Page 132: ...Maintenance and Cleaning Dynacode II IP 132 Operating Manual 03 21...
Page 138: ...Signal Diagrams Dynacode II IP 138 Operating Manual 03 21...
Page 160: ...Additional Information Dynacode II IP 160 Operating Manual 03 21...
Page 162: ...Environmentally Friendly Disposal Dynacode II IP 162 Operating Manual 03 21...
Page 167: ......