Double two-way valve (4) for blow air
In the operation mode 'Blow on' the label will blow up to the product.
In the operating modes 'Stamp on' and 'Roll on' the blow air is
switched on for a short time after each application to avoid
contaminations within the vacuum channels.
For all described functions both valves will be controlled parallel.
By pressing the keys 8 or 9 the blow air is only switched on by one of
both internal valves.
Double two-way valve (5) for vacuum / supporting air
The two internal valves serve the vacuum nozzle for connecting an in
this way for creating the negative pressure at the tamp and
independent of this for connecting the support air at the blow tube for
the label transfer.
By pressing switch 10 the vacuum is switched on and by pressing
switch 11 the supporting air is switched on.