Carimali Macco M Installation And Use Manual Download Page 13

lb.05015.01 Pag. 

13  15/12/2010 

 

 

 

OPTIONAL COMPONENTS

 

 
In order better to carry out the refurbishing procedure, we strongly recommend to purchase the following optional 
components: 
 
 

SUPPORT FOR THE 
M2 GROUP 
CODE A 0113.VE 

 
 
 
 
 
 
 
 
 

EXTENSION CABLE FOR 
GROUP, CODE 03.01151 

 
 
 
 
 
 
 
 
 
 
Please note that the extension cable can be also used to connect the group to the coffee machine, in such case it will 
be possible to leave the group on the support, thus external to the machine. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for Macco M

Page 1: ...lb 05015 01 Pag 1 15 12 2010 TEST BENCH FOR M GROUP WITH ENCODER EN ENGLISH LB 05015 01 EDITION DECEMBER 2010 INSTALLATION AND USE MANUAL...

Page 2: ...lb 05015 01 Pag 2 15 12 2010...

Page 3: ...e are allowed to use and maintain it The machine must not be used by children or people with reduced mobility sensory mental or lack of experience or education unless there is a supervisor After unpac...

Page 4: ...brown 8 lower motor red 9 lower motor black 10 encoder mot inf blue 11 encoder mot inf black 12 encoder mot inf brown STANDARD CONNECTOR TO CONNECT THE COMPLETE GROUP TO THE TEST BENCH ELECTRICAL CON...

Page 5: ...vailable key are the one highlighted See below the key highlighted by default Key 1 carries out 1 cycle Key 2 carries out 10 cycles Key 3 carries out 20 cycles Key 4 carries out 30 cycles Key 5 carrie...

Page 6: ...e used to start the movement of the motor Arrow which indicates the direction of the movement Character which indicates the status of the peak current motor not in peak current I motor in peak current...

Page 7: ...Keypad function B1 and B2 to move the upper motor B3 and B4 to move the sweeper motor B5 and B6 to move the lower motor During the group movement the following data are displayed Pulses read by the e...

Page 8: ...keeping pressed the SHIFT key for 5 seconds the display shows the main menu as we would be entered with Factory password which allow to see all parameters The display shows INFO RESET The INFO RESET m...

Page 9: ...l cursor must be located on the character you want to select To scroll the character use the keys Press Enter key to confirm the selection Use key B1 to skip at the end of the name Use key B2 to delet...

Page 10: ...MANAGER Once the SYSTEM CLOCK PROGRAMMING menu is selected the display shows SYSTEM MANAGER SYSTEM CLOCK PROGRAM ALARM HISTORY DISPLAY REGULATION GROUP CYCLE TEST TEST ACTUATORS EXPELLER TEST GROUP M...

Page 11: ...ds the display shows Esc PRESET CONFIGURATION SERVICE TECHNICIAN FACTORY PRESET CONFIGURATION FACTORY Enter Esc By power OFF and power ON it is meant clearing and giving voltage to the test bench by m...

Page 12: ...2 15 12 2010 The following sub menus are not useful for the test bench ALARM HISTORY DISPLAY REGULATION For the following sub menus please refer to the FUNTIONING chapter GROUP CYCLE TEST TEST ACTUATO...

Page 13: ...mend to purchase the following optional components SUPPORT FOR THE M2 GROUP CODE A 0113 VE EXTENSION CABLE FOR GROUP CODE 03 01151 Please note that the extension cable can be also used to connect the...

Page 14: ...specifications of the equipment illustrated in this publication the manufacturer declines all responsibility for any mistakes due to printing and or typing errors contained in this publication All ins...