Technical user manual SLC
B-control
www.cargofloor.com
www.cargofloor.com
Page 22
Version 01 / July 10
th
, 2017
FUNCTION OF B-CONTROL SWITCHES
CF 4 SWITCH (MAIN CONTROL)
The standard supplied remote control CF
4, with 10 meter [30’] of cable, is used for the day-to-day control
of the system. After you have manually put the handle in the loading / unloading function, the moving floor
system can turned on / off by using the electrical switch.
The CF4 switch has the following functions:
The CF4 switch has a plug connector, which can be inserted into the connector of the CF3 switch and
screwed tight.
TO DISCONNECT THIS, THE DUCT MUST BE UNSCREWED, AFTER WHICH THE PLUG CAN BE
PULLED OUT. NORMALLY, THIS PLUG SHOULD ALWAYS BE CONNECTED TO THE
CONNECTOR.
CF3 SWITCH
The CF3 switch is the permanent switch which is mounted in the control box and has 3 switch positions
with the following functions:
In the interest of safety this switch is fitted with an automatic spring-back for position I and II, so that it
always returns to “0” position. This is necessary to prevent conflict situations arising when using the CF4
remote control.
Mounted below the CF3 switch, is a connector to which the CF4 switch or the RX RECEIVER can be
connected without the need for any adjustments. Normally, the CF3 switch should only be used if the
CF4 switch is defective.
If, after the initial assembly, the switch does not work it is probably because the connections for the +
(brown) and the
– (blue) have been swapped around. The supply cable contains a blocking diode which
prevents damages arising from the + and - from being connected in reverse.
A 2 Amp fuse has been mounted in the CF3 switch. Never mount a fuse over 3A, this can cause damage
to the electrical installation.
When turned left or right, it will start the floor and when
released it will automatically return to the 0 position
Red STOP button
Push in for an immediate STOP.
Deactivate by turning.
Turn right, it will start the
transport floor and when
released it stays
locked.
Rotary switch
Turn left, it will start the
transport floor and when
released it will
automatically return to the
stop position
Red STOP button
Push in for an
immediate STOP.
Deactivate by turning.