Disposal of the product
The appliance (or the product) must be disposed of separately in accordance with the local waste disposal
legislation in force.
WARNING:
separate as much as possible the probe and digital input signal cables from the cables carrying
inductive loads and power cables to avoid possible electromagnetic disturbance. Never run power cables
(including the electrical panel wiring) and signal cables in the same conduits.
NO POWER
& SIGNAL
CABLES
TOGETHER
READ CAREFULLY IN THE TEXT!
Table of parameters
Parameter
Min. Max. Def. UOM
PS
PASSWORD
0
99
22
-
/
PROBE PARAMETERS
/5
Select °C / °F ( 0 = °C; 1 = °F)
0
1
0
-
/6
Disable decimal point (1 = disabled)
0
1
0
-
/C1 Probe calibration (OFFSET)
-50.0 50.0 0.0
°C/°F
r
CONTROL PARAMETERS
St
Setpoint (control temperature)
-50.0 90.0 3.0
°C/°F
rd
Control differential (hysteresis)
0.0
19.0
2.0
°C/°F
c
COMPRESSOR PARAMETERS
c0
Comp. and fan start delay after start-up
0
100
0
min
c1
Min. time between successive comp. starts
0
100
1
min
c4
Compressor safety (duty setting)
0
100
15
min
d
DEFROST PARAMETERS
d0
Type of defrost (0 and 1= defrost by temperature; 2, 3 and
4= defrost by time)
0
4
2
-
dI
Interval between defrosts
0
199
6
h/min
dP
Max. or effective defrost duration
1
199
20
min/s
d4
Defrost when the instrument is switched on (1= activated)
0
1
0
-
d6
Disable temperature display during defrost (1= display disabled)
0
1
1
-
A
ALARM PARAMETERS
A0
Alarm differential
-20.0 20.0
-2.0
°C/°F
AL
Low temperature alarm threshold/deviation
-50.0 250.0 -5.0
°C/°F
AH
High temperature alarm threshold/deviation
-50.0 250.0 15.0 °C/°F
Ad
Low and high temperature alarm delay
0
199
0
min
H
OTHER SETTINGS
H2
Enable keypad
0= keypad disabled
1= keypad enabled
2= keypad enabled except for ON/OFF function
0
2
1
-
EY
Restore the Default settings
0
1
0
-
Table of alarms
Alarm code
Description
Parameters involved
E0
probe 1 error= control
-
LO
low temperature alarm
[AL] [Ad]
HI
high temperature alarm
[AH] [Ad]
EE
unit parameter error
-
EF
operating parameter error
-
dF
defrost running
[d6=0]
Pd
defrost awaiting execution
-
How to restore the Default settings (refer to table of parame-
ters in this sheet)
1) Access parameter EY (entering password 22 and scroll parameter list).
2) Select the desired confi guration:
• EY = 0
¼
No changes;
• EY = 1
¼
Restore of default settings (refer to Table of parameters in this sheet);
3) Exit the setting procedure (holding SET button for more than 3 s).
4) Power off the device and then power it on again while holding SET button.
5) The display shows “CE” to indicate that the confi guration has been restored.
Switching the device ON/OFF
Press UP for more than 3 s. The control and defrost algorithms are now disabled and the
instrument displays the message “OFF” alternating with the temperature read by the set probe.
Manual defrost
Press DOWN for more than 3 s (the defrost starts only if the temperature conditions are valid).
Continuous cycle
Press UP and DOWN together for more than 3 s.
Technical specifi cations
power supply
230 V 1~, -10% +15% 50/60 Hz
rated power
3 W
input
NTC probe
relay output
16 A relay UL: 12 A resistive 5 FLA, 30 LRA 240 Vac 30,000 cycles
EN60730-1: 12(2)A or 10(4)A (N.O. only) 250 Vac 100000 cycles;
type of probe
Std CAREL NTC 10 K
Ω
at 25 °C
power supply/
relay output
connector
- screw terminals pitch 5mm for cables with cross-sect. from 0.5 mm
2
to 1.5 mm
2
;
12 A max;
probe connector screw terminals:
- 2-pin pitch 5mm for models with 1 probe (cable cross-section from 0.5 mm
2
to
1.5 mm
2
); 12 A max;
assembly
using screws from the front or with brackets at the rear
display
LED display, 2 digits plus sign, decimal point and compressor icon
keypad
3 buttons with membrane
operating conditions
-10T50 °C - humidity <90% rH non-condensing
storage conditions
-20T70 °C - humidity <90% rH non-condensing
range of measurement
-50T90 °C (-58T194 °F) - resolution 0.1 °C/°F
front panel index of protection
panel installation with IP65 type 1
case
plastic terminal, 81x36x38 mm
classifi cation according to protection
against electric shock
Class II
environmental pollution
II
PTI of the insulating material
250 V
period of stress across the insulating
parts
long
category of resistance to heat and fi re
category D (UL94 - V0)
immunity against voltage surges
category 1
type of action and disconnection
micro-disconnection 1C
no. of relay automatic operating cycles EN60730-1: 100,000 cycles
UL:
30,000 cycles (250 Vac)
software class and structure
Class A
cleaning the instrument
Only use neutral detergents and water.
cable max. lenght
serial: 1 km
probes: 30 m
relay: 10 m
Note:
do not run the power cable less than 3 cm from the bottom part of the device or from the
probes;
for the connections only use copper wires
.
Safety standards
compliant with the relevant European standards. Installation precautions:
the connection cables must guarantee insulation up to 90 °C;
•
for 12 Vac versions use Class II transformers. To ensure compliance with the immunity
•
standards (surge), the transformer must be one of the models specifi ed (see the CAREL price
list). For the 12 Vac/dc versions, as double insulation cannot be guaranteed between the
power supply and the relay outputs, only use safety low voltage loads (up to 42 V effective
rated value);
ensure a space of at least 10 mm between the case and the nearby conductive parts;
•
digital and analogue input connections less than 30 m away; adopt suitable measures for
•
separating the cables so as to ensure compliance with the immunity standards;
Secure the connection cables of the outputs so as to avoid contact with very low voltage parts.
IMPORTANT WARNINGS
The CAREL product is a state-of-the-art device, whose operation is specifi ed in the technical documentation
supplied with the product or can be downloaded, even prior to purchase, from the website www.carel.com.
The customer (manufacturer, developer or installer of the fi nal equipment) accepts all liability and risk relating
to the confi guration of the product in order to reach the expected results in relation to the specifi c fi nal instal-
lation and/or equipment. The failure to complete such phase, which is required/indicated in the user manual,
may cause the fi nal product to malfunction; CAREL accepts no liability in such cases. The customer must use
the product only in the manner described in the documentation relating to the product. The liability of CAREL
in relation to its products is specifi ed in the CAREL general contract conditions, available on the website www.
carel.com and/or by specifi c agreements with customers.