G GHIURVWSDUDPHWHUV
G type of defrost (0= heating element,1= hot gas,
2= water or element by time, 3= hot gas by time)
& 0 3 flag 0
G, interval between two defrosts
F
0
199
hours
8
GW end defrost temperature
F
-50
+127
°C/°F 4
G3 maximum defrost duration or effective duration when G=2 or 3
F
1
199
min
30
G defrost at instrument on (0=no, 1=yes)
& 0 1 flag 0
G defrost delay when the unit is turned on or from digital input ($ or $ =4)
& 0 199 min 0
G display off during defrost (0=no, 1=yes)
& 0 1 flag 1
GG dripping time after defrost
F
0
15
min
2
G alarm bypass time after defrost
F
0
15
hours
1
G priority of defrost over compressor protection (0=no, 1=yes)
& 0 1 flag 0
G display defrost probe temperature
F
-
-
°C/°F
-
G& time basis (0=hours/min, 1=min/s)
& 0 1 flag 0
$ DODUPSDUDPHWHUV
$ alarm and fan differential
& 0 +19 °C/°F 0
$/ low temperature alarm (indicates the maximum variation allowed in respect to the
Set Point). If set = 0 excludes the low temperature alarm
F 0 +127
°C/°F
0
$+ high temperature alarm (indicates the maximum variation allowed in respect to the
Set Point). If set = 0 excludes the high temperature alarm
F 0 +127
°C/°F
0
$G temperature alarm delay
& 0 199 min 0
$ digital input configuration
& 0 4 - 0
$ detection time delay for the alarm input ($ = 1)
& 0 199 min 0
) IDQSDUDPHWHUV
) fan management: 0 = fans always on except specific phases (see parameters ),
), and )G); 1=fans controlled according to the temperature of the evaporator and
excluding the phases
), ), )G.
& 0 1 flag 0
) fan on temperature: if )=1;
) is the fan ON Set Point (evapor. T < Set Point()))
F -50 +127 °C/°F 5
) fans off with compressor off (0=no, 1=yes).
& 0 1 flag 1
) fans off in defrost (0=no, 1=yes).
& 0 1 flag 1
)G off in post dripping.
F
0
15
min
1
+ RWKHUVHWWLQJV
+
serial
address
0
199 - 1
+ PJ32S 0=T op.; 1=S op. with defrost
PJ32C selection of alarm relay operation
0=alarm normally not energised, 1=alarm normally energised
& 0 1 flag 1
+ 0=buttons disabled;
& 0 1 flag 1
+ only PJ32S 0=buzzer enabled 1=buzzer disabled
& 0 1 flag 0
+ identification code (or model number)
F
-99
+99
10
(*)
W
external parameter (used only for the external options)
F
-127
+127
-
-
7DE
(*):parameter
+ can only be set using the serial connection and is always visible at level F.