3.   THERMOSTAT CAREL IR33W-  SET PARAMETERS FRIDGE CABINETS

1

 

4.  Press “

Set

” (4) to view or change the values within parameter code. 

5.  Use the “

UP

’ and “

Down

” arrow keys (3) 5)  to increase or decrease value of parameter code. 

6.  Once you have required value press “

Set

” (4) to save. 

7.  Repeat  steps  3  to  6  to  set  other  parameters.  The  icons  shown  on  the  display  correspond  to  the 

category of parameter (see table below). 

8.    To permanently save the values and exit, press 

“Prg/mute”

 and hold for more than 5 seconds.

                       OPERATING INSTRUCTIONS CAREL IR33 (G60875, G60890)

 

 

AS A THERMOMETER ONLY

:

 

       

  

  

 

 

 

 

1

2

3

4

5

2 3

4 5

Carel ir33 

           

         Control Keys   

 

Display 

 

 

ENGINEER  ONLY  SETTINGS,  PLEASE  READ  AND  UNDERSTAND  FULLY  BEFORE  PROCEEDING

 

 

Factory  Reset  (only required if parameters in table below have been unknowingly changed) 

 

1.  To set default parameter values switch off instrument. 
2.  Switch back on, hold “

Prg/ mute

 

 key (2) until the message “Std ” is shown on the display. 

 

How  to  change  the  SET  PARAMETERS

  

 

1.  To access the set parameter codes- press and hold “

Prg /

 

mute

“ (2) & “

Set

” (4) keys together for 5 

seconds. The display will show “00”. 

2.  Press the “

UP

” arrow key (3) until you reach value 

22

 and then press “

Set

” (4) to confirm (you will 

now be in the configuration parameters) 

3.  Use the “

UP

’ and “

Down

” arrow keys (3) (5) to change between parameter codes (see table on next

   

page for codes)

.  

TO SET THE IR33 AS A TEMPERATURE DISPLAY ONLY (Thermometer)

1.  Compressor ON
2.  Key “

Prg/ mute

”    

3.  Key “

UP

4.  Key “

Set

5.  Key “

DOWN