background image

C

AREFREE OF 

C

OLORADO

 

I

NSTALLATION 

M

ANUAL

 

T

RAVEL

'

D

IRECT 

R

ESPONSE

 

052567-001r5 

 

Match Colors
Red to Red
Black to Black

Motor Patch
Cable

Route module wires
down and behind motor,
connect to 
motor patch cable

Connect switch wires
to module wires
(match colors)

Rear

Cover

Motor

Assy

Motor

Cable

Press New Cable

into Open Groove

of Front Channel

Press New Cable into
Open Groove of Channel #2

Clean this surface

Cutoff Tab from

Bottom of Front Cover

DETAIL 

A

12V Direct Response

Control Module

060686-001

Rev 1.0

DETAIL 

C

DETAIL 

D

DETAIL 

E

To Switch

DETAIL 

F

Front
Channel

Channel #2

Alternate
Switch
Routing

LCDR001a

Double Sided

Tape

Switch
Cable

3.5"

DETAIL 

B

Cord

Retainer

Motor
Patch Cable

Route long red & black
module wires inside arm
to motor cable

Front

Cover

Ø 5/16" Hole

Switch Cable

Top of Channel Routing

Bottom of Channel Routing

Ø 5/16" Hole

Switch Cable

Alternate
Routing

Summary of Contents for DIRECT RESPONSE

Page 1: ...stallation TABLE OF CONTENTS Prior to Installing the Kit 3 Installing the Sensor 4 Switch Installation 7 Wiring an Additional Extend Retract Switch 8 Attach the Label 8 Read this manual before installing or using this product Failure to follow the instructions and safety precautions in this manual can result in personal injury and or cause the product to not operate properly Carefree of Colorado 2...

Page 2: ...al personal injury hazards Obey all safety messages that follow this symbol to avoid possible personal injury or death WARNING Indicates a hazardous situation which if not avoided could result in death or serious bodily injury CAUTION Indicates a hazardous situation which if not avoided may result in minor or moderate bodily injury NOTICE Indicates a situation that may result in equipment related ...

Page 3: ... exterior wall as described in the awning installation instructions These instructions replace the switch and wiring directions included with the awning For Existing Installations The installer must locate and remove any existing switches Access to the motor cable and the 12VDC Ground wires is required 1 Determine the location of the switches 1 1 Do not mount the switches near heat producing eleme...

Page 4: ...6 Detach the motor assembly from the arm 7 For units that had the emergency terminals on the rear cover refer to Detail C for units without the emergency terminals go to step 8 7 1 Partially pull the motor cable from the rear of the arm approximately 9 10 7 2 Cut the cable approximately 7 from the top of the channel Remove but DO NOT discard the cable that was cut 7 3 On the cable remaining in the...

Page 5: ...nnel Press New Cable into Open Groove of Channel 2 Clean this surface Cutoff Tab from Bottom of Front Cover DETAIL A 12V Direct Response Control Module 060686 001 Rev 1 0 DETAIL C DETAIL D DETAIL E To Switch DETAIL F Front Channel Channel 2 Alternate Switch Routing LCDR001a Double Sided Tape Switch Cable 3 5 DETAIL B Cord Retainer Motor Patch Cable Route long red black module wires inside arm to m...

Page 6: ...wiring diagram is on page 7 17 In the front channel attach the red and black wires from the module to the motor cable inside the channel 18 Secure the red and black wires into the groove of the front channel using a 2 piece of cord retainer 19 Attach the rear cover 20 Detail D Cut or break off the tab on the bottom of the front cover Attach the front cover 21 Detail E Route the new cable down the ...

Page 7: ...erminal of the ON OFF switch 5 Terminate the BLACK wire from the motor cable with a 25 14 16 awg male terminal 6 Run a minimum 14 awg wire to chassis ground Suitable ground would be the vehicle chassis or conductive structure connected to the chassis Terminate the wire with 25 14 16 awg female terminal and connect to the black wire from the cable 7 Run a minimum 14 awg wire from the power distribu...

Page 8: ...END RETRACT switch wires from the switch cable Pin 1 of the additional switch should go to pin 1 of the main patio switch etc ATTACH THE LABEL After completing and testing the system attach the Direct Response identification label to the bottom of the motor arm 1 Thoroughly clean and dry the area at the bottom of the RH motor arm 2 Remove the release paper and attach the DR label in the area shown...