READ AND FOLLOW ALL INSTRUCTIONS! SAVE THESE INSTRUCTIONS!
WARNING! To reduce the risk of injury and product damage:
Feeders are designed to use only Chlorine (Trichloro-s-triazinetrione) or Bromine
(Bromochloro -5, 5 Dimethylhydantoin) tablets, slow dissolving type.
UNDER NO
CIRCUMSTANCES
MIX Trichlor OR Bromine with Calcium Hypochlorite, with other forms of
concentrated chlorine, or with other chemicals
FIRE AND/OR EXPLOSION MAY RESULT
.
NEVER
use oils or grease to lubricate 0-ring. Oil in contact with Trichlor OR Bromine may result
in
FIRE
. Caution should be used when removing feeder cap. Do not inhale fumes.
If shock treatments or Algaecides containing chemicals other than sanitizer tablets in feeder
must be used, then turn off feeder OR remove tablets until the shock or algae treatment is
complete and all granules have dissolved. Failure to do so may result
in granules mixing in feeder causing
FIRE AND/OR EXPLOSION
. The shock or algae treatment
dissolved in water is safe with tablets.
ALWAYS WEAR PROTECTION
for eyes, skin and clothing when working with chemicals. Do
not smoke and avoid sparks and open flames. Turn off pump and control valve before opening
chlorinator. Use of bulk chemicals may result in damage to pool.
Chemicals will dissolve very quickly and may cause bleaching to liner due to over-chlorinating,
possibly causing unsafe pool conditions.
Settings in excess of the recommended control setting levels for the chlorinator can result in
excess chlorine being discharged in your pool. This can result in bleaching or discoloration of
areas around the pool inlet or in some cases bleaching of the entire pool liner or paint (
CHECK
CHEMICAL RESIDUALS REGULARLY
).
MOTOR DOES NOT START:
Make sure motor is plugged in.
Circuit breaker in OFF position.
Thermal overload in tripped position.
WIRING INSTALLATION INCORRECT:
Incorrect line voltage.
Defective
wiring.
THERMAL OVERLOAD TRIPS:
Low voltage.
Wiring installation incorrect.
Dual voltage pumps mis-wired.
Inadequate
ventilation.
NO WATER FLOW:
Obstruction of suction or return line.
Clogged
impeller.
Suction system air leaks.
Slice valve closed.
Clogged hose fitting.
Clogged
basket.
Dirty
sand.
EXCESSIVE PUMP NOISE:
Worn bearings.
Suction line clogged.
Pump incorrectly mounted.
Hose fitting partially closed.
Slice valve partially closed.
Clogged trap basket.
INADEQUATE FILTERING:
Sand level too low.
Inadequately cleaned system.
Excessive dirt load.
Chemical
imbalance.
Inadequate system pressure.
CHLORINATOR & BROMINATOR USE WARNINGS
TROUBLESHOOTING
Model FS01619 - 100 lbs.
Model FS01922 - 150 lbs.
Model FS02225- 250 lbs.
Model FS02629 - 400 lbs.
SAND FILL CHART:
LIMITED WARRANTY
Waterway Plastics manufactures its products and equipment in accordance with very high standards of workmanship. We use the best materials
available and maintain the highest quality procedures practical in the industry. For Warranty, product must be registered at time of purchase/installation
at www.waterwayplastics.com. For Warranty claims or questions, please contact point of purchase.
810-0159.1215
©2015 Waterway Plastics
2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403
www.waterwayplastics.com • [email protected]
Designed,
Engineered &
Manufactured
in the USA.