Care of Sweden CuroCell Nova CX13 User Manual Download Page 11

11

 

 

max

 

1

 

%.

 

If

 

using

 

a

 

different

 

agent,

 

choose

 

one

 

that

 

does

 

not

 

affect

 

the

 

plastic

 

of

 

the

 

pump

 

housing.

 

 

MATTRESS

 

COVER

 

 

Covers

 

can

 

be

 

wiped

 

off

 

with

 

a

 

mild

 

cleaning

 

solution

 

for

 

this

 

purpose

 

such

 

as:

 

alcohol

 

with

 

or

 

without

 

tensides,

 

Isopropanol

 

70

 

%,

 

oxidating

 

solutions

 

or

 

chlorine

 

max

 

1

 

%.

 

Excrements

 

and

 

blood

 

spots

 

must

 

be

 

removed

 

immediately

 

with

 

cold

 

water.

 

Carefully

 

follow

 

local

 

instructions

 

and

 

usage

 

instructions

 

for

 

the

 

cleaner.

 

 

Multi

layer

 

covers

 

should

 

be

 

divided

 

before

 

washing.

 

W

ash

 

with

 

like

 

colors.

 

 

Chlorine

 

and

 

phenol

based

 

cleaners

 

could

 

have

 

a

 

negative

 

impact

 

on

 

the

 

PU

 

surface

 

and

 

should

 

be

 

avoided.

 

If

 

chlorine

 

is

 

used,

 

we

 

recommend

 

a

 

mixture

 

of

 

max.

 

1%.

 

 

INNER

 

COVER

 

AND

 

DISTANCE

 

FABRIC

 

(accessories)

 

 

 
 

Clean

 

the

 

affected

 

area

 

with

 

a

 

mild

 

cleaning

 

solution

 

for

 

this

 

purpose

 

such

 

as:

 

alcohol

 

with

 

or

 

without

 

tensides,

 

Isopropanol

 

70

 

%,

 

oxidating

 

solutions

 

or

 

chlorine

 

max

 

1

 

%.

 

 

5.2

 

Reconditioning

 

 

PUMP

 

See

 

section

 

5.1

 

for

 

instructions.

 

 

MATTRESS

 

1.

 

Disconnect

 

the

 

tubes

 

and

 

let

 

the

 

air

 

out,

 

also

 

open

 

the

 

CPR

 

valve.

  

 

2.

 

Remove

 

the

 

cover.

 

See

 

instructions

 

in

 

chapter

 

5.1

 

for

 

cleaning

 

covers.

 

If

 

the

 

product

 

is

 

equipped

 

with

 

a

 

foam

 

core

 

this

 

should

 

be

 

removed

 

and

 

cleaned

 

separately.

 

 

3.

 

Move

 

the

 

mattress

 

to

 

a

 

clean

 

area,

 

which

 

is

 

suitable

 

for

 

cleaning.

 

 

4.

 

Wipe

 

off

 

the

 

cells,

 

all

 

tubes

 

and

 

the

 

CPR

 

valve

 

with

 

a

 

mild

 

cleaning

 

solution

 

for

 

this

 

purpose

 

such

 

as:

 

alcohol

 

with

 

or

 

without

 

tensides,

 

Isopropanol

 

70

 

%,

 

oxidating

 

solutions

 

or

 

chlorine

 

max

 

1

 

%.

 

 

5.

 

Wipe

 

off

 

and

 

disinfect

 

all

 

the

 

work

 

surfaces

 

with

 

an

 

alcohol

based

 

cleaning

 

agent

 

intended

 

for

 

this

 

purpose.

 

 

6.

 

Put

 

the

 

mattress

 

together.

 

If

 

cells

 

for

 

any

 

reason

 

have

 

loosened

 

from

 

the

 

tubes,

 

these

 

must

 

be

 

replaced

 

according

 

to

 

drawing

 

in

 

chapter

 

2.1.

 

 

FOAM

 

CORE

 

 

Clean

 

the

 

affected

 

area

 

with

 

a

 

mild

 

cleaning

 

solution

 

for

 

this

 

purpose

 

such

 

as:

 

alcohol

 

with

 

or

 

without

 

tensides,

 

Isopropanol

 

70%,

 

oxidating

 

solutions

 

or

 

chlorine

 

max

 

1

 

%.

 

 

Press

 

out

 

the

 

water

 

carefully.

 

Let

 

the

 

foam

 

core

 

dry

 

in

 

a

 

warm,

 

ventilated

 

area,

 

without

 

direct

 

exposure

 

of

 

sunlight.

 

The

 

foam

 

core

 

needs

 

to

 

be

 

completely

 

dry

 

before

 

it

 

is

 

used

 

again.

  

 

 

Summary of Contents for CuroCell Nova CX13

Page 1: ...User manual 2015 08 10 CuroCell Nova CX13 CuroCell Nova CX19 Alternating pressure system Item number user manual 95 001062...

Page 2: ...roduction 4 Product description 5 Assembly Installation 7 Operation 8 Cleaning and reconditioning 19 Storage 12 Maintenance 12 Troubleshooting 13 Technical description 14 Spare parts 16 Options and ac...

Page 3: ...revents it from becoming trapped or damaged NOTE Be particularly aware of trapping damage when using bed rails 5 Never use the product if the pump power cord or plug is defective the pump casing is da...

Page 4: ...immediately to us here at Care of Sweden The system has been tested and approved according to the following standards IEC 600601 1 IEC 60601 1 2 SS EN ISO 12182 SS EN ISO 14971 SS EN ISO 10993 EN 597...

Page 5: ...ces by sending your details to info careofsweden se 2 Product description 2 1 Pump and mattress 1 Mattress 2 CPR rapid deflation 3 Pump connector 4 Pump NOTE For certain patients such as amputees are...

Page 6: ...ilated cells they are located here 9 cells Foam core Tubing system CuroCell Nova CX13 CuroCell Nova CX19 with integrated foam core and tubing system 2 2 Pump 1 Connection tubes 3 Power cord 5 Suspensi...

Page 7: ...pressure must be increased at least one 1 step Lights when the mattress is ready for use Alarms for low pressure In order to solve it see chapter 8 troubleshooting 3 Assembly Installation When unpacki...

Page 8: ...click sound when the connectors are properly attached 4 Check that the switch on the pump is in the 0 position Off Connect the plug to an approved electrical socket 220 V 4 Operation Note Always read...

Page 9: ...h the user s pelvic region and make sure that the user does not lay directly on the underlying mattress There should be about 1 2 fingers margin If you can feel the user s body resting on your hand yo...

Page 10: ...the cell remain in its place in the mattress The air cell is activated by assembling the connection again 5 Cleaning and reconditioning It is important to follow the instructions below before using th...

Page 11: ...nstructions MATTRESS 1 Disconnect the tubes and let the air out also open the CPR valve 2 Remove the cover See instructions in chapter 5 1 for cleaning covers If the product is equipped with a foam co...

Page 12: ...he plug out of the electrical socket before replacing fuses 2 Remove the cover for the fuses with a screwdriver Pull out the fuse holder 3 Fit a new fuse of the same type T1AL 250 V and screw the prot...

Page 13: ...hand check see section 4 4 Mattress moves around Check that the air mattress is secured to the underlying mattress with the elastic straps If the mattress has a built in foam pad fasten it to the bed...

Page 14: ...ssification Class II Type BF IP2X MATTRESS SPECIFICATION Model CuroCell Nova CX13 Nova CX19 Dimension LxWxH 80 85 90 105 120x200 210x13 19 cm Weight 5 2 kg 80x200 cm 8 5 kg with built in foam pad NOTE...

Page 15: ...ser manual Machine wash at 70 C CE marked acc to MDD 93 42 EEC Machine wash at 95 C Directly on bed base Tumble dry Place on top of existing mattress Do not iron Recommended user weight Patient inform...

Page 16: ...cm CC 906013 Top part Olivia grey 85x210 cm CC 906014 Top part Olivia grey 90x200 cm CC 906015 Top part Olivia grey 90x210 cm CC 906016 Top part Olivia grey 105x200 cm CC 906018 Top part Olivia grey...

Page 17: ...ntilated cells Low Air Loss Micro ventilation in 9 of the cells 11 2 Accessories For CuroCell Nova CX13 Art no Description Size CC 9093 Sturdy transport bag 80 85 90 cm CC 9094 Sturdy transport bag 10...

Page 18: ...with MDD 93 42 EEC that is used as an aid in preventing and treating pressure ulcers For this reason we recommend that the pump be regularly serviced and inspected to maintain functionality and perfo...

Page 19: ...a recycling centre and sorted as electronic waste Mattress A used CuroCell mattress must be taken to a recycling centre and sorted as combustible waste For more information please contact Care of Swed...

Page 20: ...ernet www careofsweden com Address Care of Sweden AB P O Box 146 SE 514 23 Tranemo SWEDEN Visit address Fabriksgatan 5A SE 514 33 Tranemo SWEDEN Cargo address Byns v g 4A SE 514 33 Tranemo SWEDEN Supp...