
2
3
4
5
6
7
8
10
11
9
WARNING: THIS APPLIANCE MUST BE EARTHED
Check that the power rating of the mains supply is suitable for the maximum power of the
appliance as indicated on the rating label.
The circuit breaker rating for this appliance is 16 amp.
If the appliance is supplied with a mains lead it should be “hard wired” as follows:
The “yellow/green” earth wire, which must be connected to a terminal, and has to be about
10mm longer than the other wire.
The neutral wire has to be connected to the terminal marked 'N'.
The Live wire should only be connected to the terminal marked 'L'.
Mains connection can also be made by fitting a double pole switch with a minimum gap
between the contacts of 3mm, proportionate to the load and complying with the regulations
in force.
The yellow/green earth wire should not be controlled by the switch.
When a double pole switch is used for mains supply connection it should be easily
accessed, once the appliance is in position.
IMPORTANT:
The mains supply cable should be positioned so that it is never subjected to temperatures
which are more than 50ºC above ambient temperature.
The electrical safety of the appliance can only be guaranteed when it has been correctly
connected to a properly earthed mains electrical supply, as laid down in the current
regulations for electrical safety.
The manufacturer cannot be held responsible for any damage to persons or objects due to
lack of an earth connection.
The ovens are designed to operate with a mono-phase alternating current of
220-240V, 50Hz.
Before the installation of the appliance, check the specifications on the
rating label.
Electrical Connection
Please keep this instruction manual for future reference