8525-M320-O1 Rev-B 

 DR660 Operation 

INSTALLATION 

Unpacking 

Before beginning installation of your scale, make certain the instrument has been received 
in good condition.  When removing the scale from its packing, inspect it for signs of 
damage, such as exterior dents and scratches.  Keep the carton and packing material for 
return shipment if it should become necessary.  It is the responsibility of the purchaser to 
file all claims for any damages or loss incurred during transit. 
 

1.  Remove the weight display, scale base assembly, 

hardware pack and power supply from the shipping carton. 

2.  Remove the four leveling feet from the hardware pack and 

install in each corner of bottom of scale base assembly.  

Note:

  Leveling feet must be in place to operate the scale. 

3.  For best results, place the scale on a flat level surface. 

4.  Adjust leveling feet, to ensure that the scale will sit level.   

5.  Plug-in 15VDC adapter to use scale and to begin charging 

battery pack.  Refer to POWER SUPPLY or BATTERY 
PACK sections of this manual for more instruction. 

6.  The scale is now ready for use. 

 

Power Supply 

To apply power to the scale using the included 15VDC, 300 
mA power supply, insert the plug from the power supply cable 
into the power jack on the right side of the indicator and then 
plug power supply into the proper electrical outlet.  The scale 
is now ready for operation.   

 

Battery Pack 

The scale uses a 7.2VDC, 1200 mA built-in rechargeable battery pack.  The DR660 can 
operate for approximate 8 hours of continuous use with a fully charged battery pack. 

 

Battery Charging 

To recharge the battery pack, the power supply must be connected to an AC power outlet 
and plugged into the scale.  It will take approximately 14 hours to fully recharge the battery 
pack in the scale.  While the batteries are charging the DR660 can still be operated.  Note 
that charging the battery pack for more than 14 hours 

will not

 damage it. 

 
If the power supply is disconnected before the 14 hours, the scale will continue to charge 
the battery pack when the power supply is plugged back in.  

 

Low Battery     

When the battery pack is near the point it needs to be recharged, a low battery indicator on 
the display will turn on.  If the battery voltage drops too low for accurate weighing, the scale 
will automatically shut off and you will be unable to turn it back on.  When the low battery 
indicator is displayed, the operator should plug the power supply into the scale and then 
into the proper electrical wall outlet.  The scale will begin charging the battery pack. 
 

Leveling Feet 

Leveling Feet

Summary of Contents for DR660

Page 1: ...on 1 MODEL DR660 BARIATRIC SCALE Operation Manual CARDINAL SCALE MFG CO 8525 M320 01 Rev B 203 E Daugherty Webb City MO 64870 USA 02 12 Ph 417 673 4631 Fax 417 673 2153 www detecto com Technical Support Ph 866 254 8261 tech cardet com ...

Page 2: ...ruction manual may cause interference to radio communications It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area may cause interference in which case...

Page 3: ...of Display head 10 63 W x 3 54 D x 1 77 H 270 mm x 90 mm x 45 mm Platform Size 21 5 W x 17 2 D x 1 97 H 561 mm x 444 mm x 53 mm Zero Established on power up routine and maintained by auto zero circuitry Power Built in rechargeable battery pack 7 2VDC 1200mA or 120 VAC 60Hz powering a 15 VDC 300 mA wall plug in UL CUL listed power supply Tare 100 of full scale capacity Temperature 40 to 105 F 5 to ...

Page 4: ...lug from the power supply cable into the power jack on the right side of the indicator and then plug power supply into the proper electrical outlet The scale is now ready for operation Battery Pack The scale uses a 7 2VDC 1200 mA built in rechargeable battery pack The DR660 can operate for approximate 8 hours of continuous use with a fully charged battery pack Battery Charging To recharge the batt...

Page 5: ...turned on when the weight display is stable This is turned on when a negative minus weight is displayed This is turned on when the scale weight has been zeroed This is turned on when the battery pack is near the point it needs to be recharged HOLD This is turned on after pressing the HOLD key kg This is turned on to indicate that the displayed weight is in kilograms lb This is turned on to indicat...

Page 6: ...the alternate units of measurement if selected during configuration of the scale 2 Press to select menu in the CONFIGURATION mode ON OFF ZERO 1 Press and release to turn on scale 2 Press and release to turn the scale off 3 Press to reset the display to zero up to 20 of the scale capacity TARE 1 When there is load on the scale press this key to return to zero 2 2 Press and hold for 3 seconds to ent...

Page 7: ...onal WEIGH Place the item to be weighed on the scale platform Wait a moment for the scale display to stabilize then read the weight TO RE ZERO THE WEIGHT DISPLAY To re ZERO the weight display press the ON OFF ZERO key and continue The scale will re ZERO until 20 of full capacity is reached TO TARE THE WEIGHT DISPLAY To tare the weight display press the TARE key and continue The scale will re TARE ...

Page 8: ...On or Disable display will change to OFF 5 Press the HOLD key 6 Press the lb kg key 3 times The display will change to Unit 7 Proceed to AUTOMATIC SHUTOFF To select lb pounds weighing units 1 With the display showing Unit press the HOLD key and then the lb kg key The display will change to show lb 2 Press the HOLD key to display lb status 3 Press the lb kg key to toggle between Enable display will...

Page 9: ...d should not require changing in most locations In the event that the factory settings do not meet the requirements of your location contact the factory for the value for your location With GrAu enable from the function setting of the Configuration mode the scale will use the factory set value of 9 796 for the Gravity Compensation If the GrAu is disabled the scale will use the value obtained from ...

Page 10: ...pping items on scale or other extreme shock DO NOT submerge scale or display in water pour or spray water directly on them DO NOT use acetone thinner or other volatile solvents for cleaning DO NOT expose scale or display to direct sunlight or temperature extremes DO NOT place scale in front of heating cooling vents DO clean scale and display with a damp soft cloth and mild non abrasive detergent D...

Page 11: ...8525 M320 O1 Rev B DR660 Operation 9 ...

Page 12: ...8525 M320 O1 Rev B DR660 Operation 10 ...

Reviews: