background image

8535-M212-O1 Rev A 

 MB150 

PRECAUTIONS 

Before using this indicator, read this manual 
and pay special attention to all "WARNING" 
symbols: 

 

 

IMPORTANT

 

 

ELECTRICAL 

 

 

      WARNING 

FCC COMPLIANCE STATEMENT 

WARNING!

  This equipment generates uses and can radiate radio frequency and if not 

installed and used in accordance with the instruction manual, may cause interference to radio 
communications.  It has been tested and found to comply with the limits for a Class A 
computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide 
reasonable protection against such interference when operated in a commercial environment.  
Operation of this equipment in a residential area may cause interference in which case the 
user will be responsible to take whatever measures necessary to correct the interference. 
 
You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” 
prepared by the Federal Communications Commission helpful. It is available from the U.S. 
Government Printing Office, Washington, D.C. 20402.  Request stock No. 001-000-00315-4. 
 

 

PROPER DISPOSAL 

When this device reaches the end of its useful life, it must be properly disposed of.  It must not 
be disposed of as unsorted municipal waste.  Within the European Union, this device should 
be returned to the distributor from where it was purchased for proper disposal.  This is in 
accordance with EU Directive 2002/96/EC.  Within North America, the device should be 
disposed of in accordance with the local laws regarding the disposal of waste electrical and 
electronic equipment. 
 
 
It is everyone’s responsibility to help maintain the environment and 
to reduce the effects of hazardous substances contained in electrical 
and electronic equipment on human health.  Please do your part by 
making certain that this device is properly disposed of.  The symbol 
shown to the right indicates that this device must not be disposed of 
in unsorted municipal waste programs. 
 
 
 
All rights reserved.  Reproduction or use, without expressed written permission, of editorial or 
pictorial content, in any manner, is prohibited.  No patent liability is assumed with respect to 
the use of the information contained herein.  While every precaution has been taken in the 
preparation of this manual, the Seller assumes no responsibility for errors or omissions. 
Neither is any liability assumed for damages resulting from use of the information contained 
herein.  All instructions and diagrams have been checked for accuracy and ease of application; 
however, success and safety in working with tools depend to a great extent upon the individual 
accuracy, skill and caution.  For this reason the Seller is not able to guarantee the result of any 
procedure contained herein.  Nor can they assume responsibility for any damage to property or 
injury to persons occasioned from the procedures.  Persons engaging the procedures do so 
entirely at their own risk. 
 
 

II 

Serial Number 

______________________ 

Date of Purchase 

___________________ 

Purchased From 

____________________ 

___________________________________ 

___________________________________ 

___________________________________ 

RETAIN THIS INFORMATION FOR FUTURE USE

 

Summary of Contents for Detecto MB150

Page 1: ...Model MB150 Mother Baby Scale User Manual CARDINAL SCALE MFG CO 8535 M212 O1 Rev A PO BOX 151 WEBB CITY MO 64870 10 10 PH 417 673 4631 FAX 417 673 5001 www detectoscale com Technical Support Ph 866 254 8261 techsupport cardet com ...

Page 2: ...8535 M212 O1 Rev A MB150 2 ...

Page 3: ...CTION 1 SPECIFICATIONS 1 AC POWER ADAPTOR 2 INSTALLING REPLACING THE BATTERY 3 BABY TRAY INSTALLATION 4 KEY FUNCTIONS 6 DISPLAY ANNUNCIATORS 7 LEVEL INDICATOR 7 WEIGHT UNIT SWITCH 7 HOW TO USE BMI FEATURE 8 SETTING THE AUTO OFF TIME 8 ERROR MESSAGES 9 I ...

Page 4: ...the local laws regarding the disposal of waste electrical and electronic equipment It is everyone s responsibility to help maintain the environment and to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health Please do your part by making certain that this device is properly disposed of The symbol shown to the right indicates that this device m...

Page 5: ...ncluded This manual contains information on the operation of this scale Please read it before attempting to use the scale and keep it handy for future reference SPECIFICATIONS Capacity Division Adult 330lb x 0 2lb 150kg x 0 1kg Baby 44lb x 0 02lb 20kg x 0 01kg Tray Removable to allow scale to weigh small children Weight Units lb kg Function Keys Adult On Off Hold BMI Tare Baby On Off Hold Tare Sta...

Page 6: ...te AC Power adaptor jack at front of scale The AC power jack is located on the lower front right of the scale next to the Weight Unit Switch 2 Install AC Power Adaptor into jack on front of scale as shown below AC Power Adapter Jack Weight Unit Switch ...

Page 7: ... the battery holder cover by pushing in on the tab and lifting it up 4 If installing new batteries proceed to step 5 If replacing the batteries remove all 6 batteries from the battery holder and then proceed to step 5 5 Install the 6 new AA batteries in the battery holder noting the polarity markings located in the battery holder 6 After placing all 6 batteries in the holder replace the battery co...

Page 8: ... TRAY INSTALLATION 1 Install tray from the rear of scale sliding it to the front of scale toward the display Note that arrow on tray should point to front of scale 2 Turn scale upside down to screw tray and platform together properly ...

Page 9: ...8535 M212 O1 Rev A MB150 5 BABY TRAY INSTALLATION CONT 3 Hand tighten the screws to secure the tray to the platform 4 Scale assembly is finished Turn scale over to begin weighing operations ...

Page 10: ...is key for 3 seconds to enter the BMI Body Mass Index mode to calculate body fat 3 Tare Baby and Adult Mode Press this key to zero the scale before starting the weighing operation or to zero off the weight of any item i e protective paper blanket or pad on the scale or in the baby tray 4 On Off Adult Mode 1 Press this key to turn the scale ON 2 With scale on press this key to turn the scale OFF Mi...

Page 11: ...he weight displayed is net weight Net weight is determined by zeroing the weight of an item from the scale such as protective paper blankets pads or toys This insures that only the baby or adult s weight is displayed kg The kg annunciator is turned on to indicate the weight shown is in kilograms lb The lb annunciator is turned on to indicate the weight shown is in pounds LEVEL INDICATOR Not Level ...

Page 12: ...p on to the scale 9 The scale will show the weight and then change to show the BMI value alternating between the weight and BMI value 10 Press Hold BMI button to return the normal weighing mode 11 The patient can now step off the scale SETTING THE AUTO OFF TIME 1 Press either the Adult or the Baby mode On Off key 2 Press and hold the Tare key until the display shows 3 Release the Tare key The disp...

Page 13: ...ale capacity Reduce the load and try again If the trouble still exists please call your scale service representative The load is over the limit the scale can zero when powering on Reduce the load and try again If the trouble still exists please call your scale service representative The load is under the limit when powering on Power OFF scale and try again If the trouble still exists call your sca...

Page 14: ...8535 M212 O1 Rev A MB150 10 ...

Page 15: ...8535 M212 O1 Rev A MB150 11 ...

Page 16: ...8535 M212 O1 Rev A MB150 12 ...

Reviews: