20
s 4HEINSTALLATIONOFBOTHANTIDERAILMENTBUFFERSIS
absolutely obligatory
before starting programming.
s -AKESURETHESAFETYDEVICESAREATRESTANDTHE%#5ISRECEIVINGMAINSPOWEROTHERWISEYOUWILLNOTBEABLETOENTERPROGRAMMING
s #HOOSETHETYPEOFGEAREDMOTORYOUAREUSINGFROMTHE
display menu
PAGE
s 4HESYSTEMAUTOMATICALLYSETSITSELFTOWORKWITHONEORTWOGATELEAVES
PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
1 2 3 4 5 6 7 8 9 10
ON
Dip-switch settings DS1
CAUTION:
If you change the dip settings you must memorise them; press the
"PROG"
BUTTOND)0WILLAPPEARONTHEDISPLAYINDICATINGTHATTHESETTINGSHAVE
been memorised.
Sequential command TD/CH1
$IP/. 3EQUENTIALCOMMANDOPENCLOSE
Travel direction inversion only during closing.
$IP/&& 3EQUENTIALCOMMANDOPENBLOCKCLOSEBLOCK
Automatic reclosing (DIP 2)
$IP/. !UTOMATICRECLOSINGENABLED
$IP/&& !UTOMATICRECLOSINGDISABLED
Pre-flashing (DIP 3)
$IP/. 0REmASHINGACTIVATED
$IP/&& 0REmASHINGEXCLUDED
Warning light output (DIP 4)
$IP/. 7ARNINGLIGHTOUTPUTINTERMITTENT
$IP/&& 7ARNINGLIGHTOUTPUTlXED
Indicator light (DIP 5)
$IP/. )NDICATORLIGHTINTERMITTENT
*
$IP/&& )NDICATORLIGHTlXED
*
The indicator light flashes slowly during opening, rapidly during closing; remains
lit when the gate is blocked but not completely closed
and is off when the gate
is completely closed.
FTCI mode (DIP 6)
$IP/.
FTCI
also active when the gate is blocked
If the photocells are in alarm and the gate is blocked, no movement commands
will be accepted (even opening commands).
$IP/&&
FTCI
active only during closing
In both cases activating the
FTCI
safety device during the closing stage will force
travel direction inversion.
FTCI test (DIP 7)
$IP/.
FTCI
test enabled
$IP/&&
FTCI
test disabled
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (
CTRL
30 Vdc
). When the test is enabled
one second will pass between receiving a command and carrying it out.
FTCS test (DIP 8)
$IP/.
FTCS
test enabled
$IP/&&
FTCS
test disabled
If you enable the security test you will have to connect both the transmitter and
the receiver to the controlled load output (
CTRL
30 Vdc
). When the test is enabled
one second will pass between receiving a command and carrying it out.
Opening direction gate delay (DIP 9)
$IP/. /PENINGDIRECTIONGATEDELAYENABLED
$IP/&& /PENINGDIRECTIONGATEDELAYDISABLED
If you enable gate delay the following will occur: during the opening movement
gate leaf 1 moves first and then gate leaf 2. In the closing direction gate leaf
2
moves first then gate leaf 1. If gate delay is disabled both gate leaves move
simultaneously.
Electric lock (DIP 10)
$IP/. %LECTRICLOCKENABLED
$IP/&& %LECTRICLOCKDISABLED
If the electric lock is enabled the ELS output (binding post 8) will be activated
before gate leaf 1 moves and will remain active until gate leaf one has moved a
few centimetres.
WHEN THE GATES REACH THE COMPLETELY OPEN POSITION THEY INVERT THE TRAVEL
DIRECTION AND AFTER MOVING FOR A FEW CENTIMETRES THEY WILL OPEN AGAIN TO
CONFIRM THE COMPLETELY OPEN POSITION. AT THIS POINT THE LEAVES MOVE ONE AT A
TIME IN THE CLOSING DIRECTION (FIRST GATE LEAF 2). WHEN ONE OF THE GATE LEAVES
REACHES THE COMPLETELY CLOSED POSITION IT INVERTS THE TRAVEL DIRECTION AND
AFTER MOVING FOR A FEW CENTIMETRES IT WILL CLOSE AGAIN TO CONFIRM THE
COMPLETELY CLOSED POSITION.
AFTER HAVING CARRIED OUT THIS MANOEUVRE THE LOGIC CONTROL WILL OPEN THEN
CLOSE THE GATE LEAVES COMPLETELY IN ORDER TO CALIBRATE THE CURRENT SENSOR.
WHEN THE GATE REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL HAVE
TO REPEAT THE
PROGRAMMING PROCEDURE.
PRESS THE
PROG
BUTTON FOR MORE
THAN 4 SECONDS: THE
PAUSE
39-"/,
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
1...4... sec.
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE DOOR OPENS
SLOWLY IN ORDER TO FIND
THE COMPLETELY OPEN
POSITION.
THE PAUSE TIME COUNT
WILL START (
MIN. 2
SECONDS: MAX 120
SECONDS
) INDICATED BY
THE
PAUSE
39-"/,
FLASHING ON THE DISPLAY
PRESS PROG
ATTENTION!
IF THE GATE MOVES
IN THE CLOSING DIRECTION THE
MOTOR CONNECTION IS
INCORRECT. PRESS “
PROG
”
AGAIN TO CANCEL THE
PROGRAMMING PROCEDURE,
INVERT THE MOTOR
CONNECTION (RED AND BLACK
CABLE) AND REPEAT THE
PROGRAMMING PROCEDURE.
CURRENT SENSOR
The programmer checks the electrical input to the motor, detecting any eventual
increase in effort above the normal operating limits and intervenes as an addi-
tional safety device. When the sensor intervenes the gate automatically inverts
the travel direction.
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON
1 2 3 4 5 6 7 8 9 10
ON