14 

Part number 3C4480 R10 

 

May 2005 

Icons 

The Prox Plus Mifare reader displays the following icons on the 
liquid crystal display (LCD) to indicate the access status of the zone 
controlled by the reader. 
 

 

Summary of Contents for Prox Plus Mifare

Page 1: ...lectrostatic discharge Ensure both you and the equipment are earthed before beginning any servicing Before you begin Unpack the Prox Plus Mifare reader and check that you received the following items...

Page 2: ...h mode power supplies are not recommended as they may reduce the read range of the Prox Plus Mifare reader Firmware The reader firmware has two variants These are set out in the table Firmware identif...

Page 3: ...lays each of its icons in sequence Displays each of its icons in sequence a second time Displays all icons simultaneously Displays a blank screen for about two seconds Displays the secure icon The ver...

Page 4: ...FT Reader I O Interface Cardax FT URI Use 4 core 0 2 mm AWG 24 cabling with a maximum nominal capacitance of 120 pF m With this type of cable the maximum distance between the Prox Plus Mifare reader...

Page 5: ...approximate The Prox Plus Mifare reader is designed to be mounted on any solid flat surface including metal surfaces The recommended mounting height for the Prox Plus Mifare reader is 1100 mm from flo...

Page 6: ...stalled for the Prox Plus Mifare reader to comply with the environmental specification Note It is very important that the base of the reader is flush with and tight against the mounting surface If you...

Page 7: ...ther of two ways use the four pin socket and cord supplied with the reader and join the cord to the building cabling or provide your own Molex 6471 crimp terminal socket and terminate the building cab...

Page 8: ...IV readers Refer to the following diagram for the location of the ports on the Cardax FT Controller 3000 P4 P3 P1 P2 P4 PF4 PF3 PF2 PE4 PE3 PE2 PF1 PE1 DETECTOR LED RS485 PA4 PA3 PA2 PA1 PA4 POWER OU...

Page 9: ...to Port 1 of Group 1 Port 2 of Group 1 can only connect to another Cardax IV reader The terminating resistors J1 for Group 1 J2 for Group 2 etc must NOT be fitted for those groups to which Prox Plus M...

Page 10: ...fare Readers Reader I O Interface 4 3 2 1 Red White Blue Black Reader A PA IN OUT Power PD V 0 Group x8 4 3 2 1 Red White Blue Black Reader B PB IN OUT For the location of the plugs on the Reader I O...

Page 11: ...ay Outputs R1 p1 Normally closed R1 p2 Normally open R1 p3 Common R2 p4 Normally closed R2 p5 Normally open R2 p6 Common p7 Ground P5 Power Comms pins 1 2 RS485 pin 3 13 6 V 15 pin 4 0V SW1 Device add...

Page 12: ...r of the base plate 5 On the front of the facia press down on the Cardax label until the security screw hole lines up with the M4 threaded hole underneath the base plate 6 Pass the M4 security screw t...

Page 13: ...Note Gallagher Part number 3E1016 for initialisation instructions Initialisation of the Cardax FT Reader I O Interface does not require prior connection to the Prox Plus Mifare reader The Prox Plus Mi...

Page 14: ...14 Part number 3C4480 R10 May 2005 Icons The Prox Plus Mifare reader displays the following icons on the liquid crystal display LCD to indicate the access status of the zone controlled by the reader...

Page 15: ...nterference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on t...

Page 16: ...ure accuracy neither Gallagher Group Limited nor any employee of the company shall be liable on any ground whatsoever to any party in respect of decisions or actions they may make as a result of using...