![Carbon MCS-352 Service Manual Download Page 12](http://html1.mh-extra.com/html/carbon/mcs-352/mcs-352_service-manual_2555726012.webp)
Before You Begin
First Time Operation
NOTE
The following process is used to flush factory-
testing fluids out of your new machine, and is
only necessary before the first time you use
the unit.
1.
Verify that the fuel filter is connected and securely in place on the side of the cabinet
.
2.
Check the output/return hoses, battery connections, and all external components for damage
.
3.
Turn
the
Gasoline (Petrol)
PRESSURE REGULATOR
on the unit’s
control panel
counterclockwise until it is completely open
.
4.
Attach the unit to the vehicle's battery by connecting the
red
battery clip to the positive (
+
)
battery terminal and the
black
battery clip to a solid ground point as far from the battery as
possible. Press the
SERVICE SELECTOR
switch to the side with
Gasoline (Petrol) FUEL
SYSTEM SERVICE
.
5.
Fill the reservoir on the right side with
clean gasoline (petrol)
until the
tank level
indicates 1/4 tank
.
See notes on page 3-2 and figure 3-3 for alternate filling procedure.
6.
Connect the output (
red
) hose and return (
black
) hose together by using the
#060-1400 adaptors and securing them with a clamp. Follow the procedures below to flush
fuel through the system:
•
Set
SERVICE SELECTOR
to
gasoline (petrol)
SERVICE SYSTEM
.
•
Set the
TIMER
knob for five minutes.
•
Press the
ON/OFF
switch to the
on
position.
NOTE: Alarm will sound continually
until pump starts.
•
Press and hold the
START/RUN
switch for five minutes.
•
Release the
START/RUN
switch.
•
Turn
off
the
ON/OFF
switch.
7.
Disconnect the output and return lines.
8.
Connect the #060-1400 adaptor to the output hose, then drain the gasoline from the reservoir
using the following procedure:
Summary of Contents for MCS-352
Page 6: ...MCS 352 BACK VIEW POWER CORD DIESEL TANK GASOLINE TANK...
Page 38: ...Diesel Cleaning Setup You are now ready to perform the Diesel cleaning procedure FIGURE C...
Page 46: ...Diesel Cleaning Setup You are now ready to perform the Diesel cleaning procedure FIGURE C...
Page 51: ...ELECTRICAL SCHEMATIC MCS 352 ECS 350...
Page 52: ...FLOW CHART MCS 352 GAS SYSTEM ECS 350...