background image

Installation Instruction

IMPORTANT INSTALLATION NOTES

AFTER INSTALLATION,PLEASE CHECK AND TEST:

WARNING:

MAINTENANCE:

Power Selectable SIZE2~SIZE4

Rack & Pinion Door Closer

Door closer SIZE2/3/4 80kg backcheck

Instructions

CDC-1

When adjusting please note there is a MAXIMUM OF 2 TURNS.

Over adjustment will affect the performance of the closer.

In such instance our Guarantee becomes VOID.

6.Adjust length of forearm so that adjustable forearm is 

   perpendicular to frame when assembled to preloaded

   main arm.

7.Secure forearm to main arm with screws provided and

   snap pinion cap over shaft at bottom of closer.

Fixing holes

Fixing screw
Link arm

Main arm

1.Open the door leaf to its maximum opening angle and release.  The door leaf should close fully into the door frame and overcome the latch.
2.Open the door leaf  and rest the latch bolt on the striker plate.  Release the door leaf.  The door closer should have sufficient power to latch the door leaf closed.
3.Back-check provides a cushioning effect when the door is forcibly thrown open but does not serve as substiture for a door stop.

1.Check the door closer every three months to ensure all fixings are secure and adjust,if necessary,adjust the closing and latching speed and mark the door operating both functionally and smoothly.

1.Due to door closer power sizes 1&2 are NOT considered suitable for use fire/smoke door assemblies.  Therefore,the minimum spring strength allowed for fire/smoke door assemblies is spring strength 3.
2.The mechanical hold open devices must NOT be installed in fire/smoke door.
3.Door closer should NOT be opened beyond the max. opening angle of the power size you selected.
4.This door closer contains a powerful spring,which is inserted into the body under pressure.  Under circumstances should not attempt to dismantle the door closer.

Arm shoe

3.Install adjustable forearm / arm and assemble to

   frame using screws provided.
4.Install main arm to top pinion shaft using screws provided.
5.Mount closer on door using screws provided.

1.According to the information show above.

   Select power size to suit door width or weight.

   Determine installation position according to the

   power strength of closer and use template mark

   four(4) holes on door for closer and two(2) holes

   on frame for arm shoe.

2.Drill pilot holes in door for #10-13x2" all-purpose

   screws or drill and tap for M5xP0.8 machine

   screws.

Closer body

6

5

4

3

2

1

NO.1

Standard

90

NO.2

Adjust the Closing & Latching speed.

1.The door closer can control two different speeds.

2.The NO.1 speed-adjusting valve controls Closing speed,

   and the NO.2 speed adjusting valve controls the Latching speed.

Back-Check Adjustment

To increase Back-check action turn valve clockwise. To decrease,

or  to turn off Back-check action turn valve counter clockwise.

Fixing in Fig1

SIZE2

850mm

40Kg

180

180

130

80Kg

60Kg

950mm

1100mm

Power

size

Max.

Door width

Max.

Door weight

Max.

Door Opening 

SIZE3

SIZE4

Carbine Radius

14 John Hines Ave 

Minchinbury NSW 2770 

www.carbine.com.au

Baber Lock & Key New Zealand

16 Parkhead Pl  Albany 0632 NZ

www.baberlocknkey.co.nz

11006 ZINS-H1317-8Z

4

6

2

1

5

3

Back check(OPTIONAL)

NO.1 Closing

NO.2 Latching

2.Apply light oil to arm knuckle joint and door hinges.