8. Settings
WARNING
: The Controller should not be open when it is plugged in or running !
Always disconnect the solar panels and the battery before opening the charge
controller.
The controller can be configured for a particular purpose.
Charge the battery type ( Lead -acid and Gel )
To do this, open the bottom of the controller by removing the screws on the
back !
When the controller is open, there are two jumper on the board. The controller
is factory set with the jumper closed for GEL batteries.
The modify the settings, move the jumper on the connector pins.
To charge, turn the jumper which is covering both pins to cover only one cont-
act pin-see below.
Jumper close for GEL batte-
ries ( 1,2 closed )
Jumper open for lead acid
batteries ( 1,2 open )
The controller is preset to close jumper from the factory
Jumper
Battery Type
Setting jumper open
Liquid electrolyte
Setting jumper close
GEL ( VRLA battery )
After completing the setting, replace the cover and tighten it with screws.