UK
FUNCTIONAL TESTING
1. Turn on the GasCube, await the selftest until the blue
LED lights up constantly and the GasCube is ready to
use.
2. Then hold a gas lighter at the GasCube’s side openings,
press the button of the lighter so that gas exhausts, but
no flame will be produced.
3. After a few seconds, the prealarm is triggered. If you
now continue to let the gas flow into the housing, after
the prealarm an alarm is triggered.
Technical details:
Button
ON/OFF
Sensitivity
approx. 95 ppm EEC
Voltage
10 – 15 VDC
Conformity
89/336EEC, 93/68EEC
Power consumption at stand-by
100 mA
Connecting cable
red = +, black = –
Power consumption at alarm
180 mA
Dimensions in mm
55 x 87 x 24
Sound volume alarm
approx. 80 dB