30
CONNECTION OF THE POWER SUP-
PLY CABLE
Unhook the terminal board cover by
inserting a screwdriver into the two
hooks “A” (fig. 11.1).
Open the cable gland by unscrewing
screw “F” (fig. 11.2), unscrew the termi-
nal screws and remove the cable.
The new supply cable, of suitable type
and section, is connected to the terminal
board following the diagram fig. 11.3.
FEEDER CABLE SECTION TYPE HO5RR-F
230 V
3 x 1,5 mm
2
Fig. 11.1
A
F
Fig. 11.2
230 V
PE
N
L
1
(L )
2
Fig. 11.3