Instruction manual DD901BK 15
Please keep this instruction manual for future reference
The extractable unit is open manually by pushing the glass
downwards, as shown in (Fig.4); in the same way, push the glass
downwards to close it, until it is completely closed.
The motor and the lights are started by the push button panel (Fig.12).
The motor and the light are automatically switched off when the
extractable unit is closed, in case they are on.
T I M I N G
As a result of the new EU65 “Energy label” and EU66 “ Ecodesign”
regulations issued by the European Commission, which came into
force as from January 1st, 2015 , our products have been adapted to comply with these new
requirements.
All of the models complying with the energy label requirements, are equipped with new electronics
including a timer device for suction speeds control, when the air capacity exceeds 650m³/h.
Internal motor models, with maximum air capacity higher than 650m³/h, are equipped with a
timer device that automatically switches the suction speed from 4th to 3rd speed, after 6 minutes
operation.
External motor models are equipped with remote motors that, as for internal motor versions,
include a timer device that switches down the speed when it exceeds 650 m³/h. (See External
Motors Instructions).
Remote motors, whose air capacity exceeds 650m³/h at suction both 4th and 3rd speed, will
have the following by default timer control functions: The suction speed is automatically switched
1. Light ON / OFF key
2. Motor ON (1 speed) / OFF key
3. 2 speed key
4. 3 speed key
5. 4 speed key
6. 10 minutes timer
S-DD11-L
67
9
8
7
10
11
12
6
5
7
8
9
10
11
12
14
1
2
3
4
5
6
Fig.12
Fig.4
O P E R AT I N G T H E D O W N D R A F T E X T R A C TO R
6 - K E Y P U S H B U T TO N PA N E L