9
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least
30mm
. Please select
heat-resistant work surface material to avoid larger deformation caused by the
heat radiation from the hotplate. As shown below:
L(mm) W(mm) H(mm) D(mm) A(mm) B(mm) X(mm)
590 520 50 46 560 490 50
mini
Under any circumstances, make sure the ceramic cooker hob is well ventilated
good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least
760
mm.
A(mm) B(mm) C(mm) D
E
760
50 mini 20 mini Air intake Air exit 5mm
and the air inlet and outlet are not blocked. Ensure the ceramic hob is in