17
Electrical connection
YOUR HOB IS INTENDED FOR FITTED AND PERMANENT INSTALLATION.
o
Cable type: H05 RRF 3 core x 4.0 mm² (Type RR-F <HAR> marked).
o
The mains cable is not supplied with this product.
o
Before connecting the appliance, make sure that the supply voltage marked on
the rating plate corresponds with your mains supply voltage.
o
We recommend that the appliance is connected by a qualified electrician, who is
a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local
regulations.
o
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
The hob must be wired into a 25A double pole switched fused spur outlet,
having 3 mm contact separation and placed in an easily accessible position
adjacent to the appliance. The spur outlet must still be accessible even when
your hob is located in its housing.
o
The wiring in the mains lead is coloured as follows:
Brown
Live
Blue
Neutral
Green and yellow
Earth
o
As the colours of the wires in the appliance’s mains lead may not correspond
with the coloured markings identifying the terminals in your spur box, please
proceed as follows:
The
brown wire
must be connected to the terminal marked “L” (live), or
coloured
red
.
The
blue wire
must be connected to the terminal marked “N” (neutral), or
coloured
black
.
The
green and yellow wire
must be connected to the terminal marked “E”
(earth), or by the earth symbol, or coloured
green and yellow
.